Frequently asked questions

Short answers to the questions that come up most often, each with a link to the guide that has the steps.

Connecting

REXDESK does not show my logger. What should I check?

  • The REXGEN USB driver must be installed and the logger powered.
  • Look at the status bar at the bottom of the window. A connected logger shows Interface: USB (<serial>), CONNECTED, the firmware version and the configuration name.
  • Only one program can use the logger at a time. If a command-line window is using it, wait for the command to finish; if you want to use the command line, close REXDESK first.

See Connect a logger and switch between loggers.

I have two loggers plugged in. Which one is REXDESK using?

When a second logger is connected, the Select Active USB Logger window asks which one should stay active. Afterwards the status bar shows the serial number of the active logger, and the small arrow next to the USB symbol switches to the other one.

See Connect a logger and switch between loggers.

Where do I see the firmware version, the serial number and the state of the SD card?

Device ▸ Logger Information shows the logger's identity, firmware, clock, SD card and active configuration in one window.

See Read the logger information.

Setting up a recording

How do I record everything on a CAN bus?

Create a project, drag Log All from the CAN group onto the bus (CAN0 to CAN3) and set the bus speed in the Bus block. Then send the configuration to the logger with Run.

See Create a configuration and Send a configuration to the logger.

How do I keep a copy of the configuration that is on the logger before I change it?

Config ▸ Logger ▸ Save Logger Configuration To File saves the configuration exactly as the logger stores it. Config ▸ Logger ▸ Load Logger Configuration opens it as a project.

See Read the configuration that is on the logger.

How do I start or stop recording when something happens?

Use a trigger. Click Triggers on the toolbar, then New Trigger, and follow the wizard: choose Start Logging or Stop Logging, what the trigger watches (for example a CAN identifier or one of the logger's own channels) and the condition. Pre- Trigger Time (sec) keeps the seconds before the event.

See Create a trigger.

In the trigger wizard, Next does nothing. Why?

The first page needs a Trigger Action. Choose Start Logging or Stop Logging, then click Next.

See Create a trigger.

How do I use the signal names from my DBC file?

Import the DBC file into the Library pane, then link it to the bus it describes in Export Settings. Logs from that bus are then decoded into named signals when you convert them.

See Import a DBC file and link it to the buses.

How do I set what each block does (filters, analog inputs, accelerometer, sleep, storage)?

Click a block in the Configuration pane to open its settings. The reference lists every block and its options.

See Block settings reference.

The logger is mounted at an angle. How do I get correct pitch and roll?

Use Device ▸ IMU Mapping: park the vehicle level and still, click Measure level, choose which end of the logger faces the front, and click Save to logger.

See Map the IMU to the vehicle.

Getting the data

How do I get the logs off the logger?

Click Internal Storage on the toolbar, select one or more logs, click Download ▾ and choose the format.

See Download logs from the logger.

Which file formats can I save?

Download ▾ offers ReX data (rxd), ASAM MDF (mf4), ASCII Logging file (asc), Vector binary frames (blf), Peak Can Trace File (*.trc), Matlab (mat) and Comma delimited (csv). The Data Logs pane, which converts files that are already on the PC, also offers Comma separated trace (cst) and Parquet (parquet).

Keep the rxd file: every other format can be produced from it later.

See Download logs from the logger and Convert logs that are already on the PC.

Can I convert logs later, without the logger?

Yes. Open Window ▸ Data Logs, add the rxd files and choose the format under Export.

See Convert logs that are already on the PC.

Why does my CSV file have empty cells?

A CSV file has one row per sample time and one column per channel, and a value appears only in the columns that were sampled at that time. Channels that arrive at different rates therefore leave gaps in each other's rows. To put every channel on the same time step, convert with resampling: on the command line, -R 100 near -T zero duplicate duplicate gives one shared row every 0.1 s. The Export data window of the log viewer has a Resampling page for the same purpose.

See Use REXDESK from the command line, Convert logs that are already on the PC and View a log.

The download failed with "the selected recording changed, moved or is no longer available". What happened?

The logger was still recording and the partition already held its maximum number of logs, so each new log replaced the oldest one and the list on screen no longer matched the card. REXDESK does not save a log it cannot identify with certainty. Stop the recording, click Refresh and select the log again.

See Download logs from the logger.

Why do the dates of my logs look wrong, or new logs appear below old ones?

Log names and timestamps come from the logger's clock. Device ▸ Logger Information shows how far it is from the PC's clock under Logger vs PC. Set it with Device ▸ Set Device Time before recording.

See Read the logger information.

I renamed a log file and now REXDESK warns about the start time. Why?

The start time of a log is read from its file name. Restore the original name, or correct Log start time in the Data Logs pane before exporting.

See Convert logs that are already on the PC.

Can I look at a log without converting it?

Yes. Select it in Internal Storage and click Show datalog, or open a file from the PC with File ▸ Import Recorded Data. The viewer has a trace, a chart with two cursors and measurements, and a map for logs with position data.

See View a log and Open, save and find your projects.

Converting to CSV says "there is no data channels to export!". Why?

The log holds only raw CAN frames, and a CSV file needs named channels. Give the converter the DBC file for the bus, or convert to a trace format such as asc or mf4.

See Use REXDESK from the command line and Import a DBC file and link it to the buses.

Can I download and convert logs automatically, from a script?

Yes. rexdesk-cli lists and downloads the logs on a logger and converts files or whole folders, and it returns an exit code a script can test. Close the REXDESK window while a script is using the logger.

See Use REXDESK from the command line.

Live data

Can I watch the data live?

Yes. Click Live on the toolbar, then Online. List shows every record as it arrives, Fixed keeps one line per channel, Chart plots the values and 3D shows the logger's orientation. The logger's own channels, such as the accelerometer, are shown in their units.

See View live data.

Live Data says "no data yet". Why?

Nothing is arriving from the logger: either Live is switched off in the logger's configuration, or no bus or sensor is producing data. Check the Live block in the configuration.

See View live data.

Firmware

How do I update the firmware, and will I lose my configuration or logs?

Device ▸ Logger Information shows Firmware <version> is available when REXDESK carries newer firmware, with an Update to latest… button. On the test loggers the configuration and the logs on the card were unchanged after the update.

Do not disconnect the logger or close REXDESK until it has reconnected.

See Update the logger firmware.

The program

How do I get back to a project I worked on before?

File ▸ Recent Files lists the projects you opened or saved, and the Projects pane lists the folders you have used with the projects in each. Double-click a project there to open it.

See Open, save and find your projects.

The window flickers or does not draw correctly. What can I do?

Open Tools ▸ Settings and change Graphics from Automatic (DirectX 12) to another entry. The change applies the next time REXDESK starts.

See Settings.

What is new in this version?

See What's new in REXDESK 1.0.

Back to REXDESK