K-TC puts 8, 16 or 32 thermocouples on the CAN bus as frames, time synchronised with the vehicle data, so temperatures and network signals land in one recording.

In the customer's words

  • We use the K-TC16 to provide a cost-effective way of adding thermocouples to the CAN bus for temperature measurement and feedback control.

    Paul DickinsonTechnical Specialist, CamMotive

  • …I'm quite happy that the temperature measurement is comparable to the kit we're using currently, within 1°C

    Powermotive

  • The K-TC units engineered by Influx Technology produce accurate and reliable results at a very competitive price.

    Paul BatesLead Instrumentation Engineer, Lotus Cars UK

  • 32 Thermocouples per K-TC module
  • ±1 °C From −200 °C to +1,200 °C
  • 20 Hz Maximum rate per channel

The thermocouple setup

Read the detail

Durability, winter and summer testing, brake and exhaust work and battery programmes all need many thermocouples, and the readings are only useful when they line up with what the vehicle network was doing at the same instant. Two clocks in two files is the problem.

K-TC in 8, 16 or 32 channel modules, stackable, with K, J and T thermocouple types over a −200 °C to +1,200 °C range at ±1 °C. Each module puts its channels on the CAN bus as frames, time synchronised with the vehicle data, at up to 20 Hz per channel, and can also log standalone to internal eMMC. K-CAL sets the CAN identifiers, bit rate and sampling rates and exports the DBC file the logger or any third-party tool needs. Functional galvanic isolation between power, USB, CAN and each group of eight channels. Record with REXGEN 2 on channel one for the vehicle bus and channel two for the K-TC segment, or with REBEL CT or REBEL LT.

  1. 01Connect

    8, 16 or 32 thermocouples into each K-TC module

  2. 02Configure

    K-CAL sets the CAN identifiers and rates and exports the DBC file

  3. 03Record

    REXGEN 2 records the vehicle bus and the K-TC segment together

The hardware

  • Thermocouple data logger

    K-TC

    From £1,299 ex VAT £1,558.80 inc VAT
  • Evidence data logger

    REXGEN 2

    £599 ex VAT £718.80 inc VAT
One recording
  • Thermocouple channels as decoded signals
  • The bus traffic beside them
  • One time base

The recording

What the recording contains

One MDF4. Export to CSV or MATLAB for thermal analysis.

Read more

Understanding CAN DBC files

What a DBC file holds and how it turns raw CAN frames into readable engineering values. With a live signal decoder and a byte-order...

Questions engineers ask

Question not answered?

Ask an engineer

Which thermocouple types and range does K-TC cover?

K, J and T thermocouple types over a −200 °C to +1,200 °C range at ±1 °C.

How fast does K-TC sample?

Up to 20 Hz per channel. Each module puts its channels on the CAN bus as frames, time synchronised with the vehicle data.

Do I need a DBC file?

K-CAL sets the CAN identifiers, bit rate and sampling rates and exports the DBC file the logger or any third-party tool needs.

Can K-TC log without a data logger?

Yes. It can also log standalone to internal eMMC.

Which loggers record K-TC?

REXGEN 2, with channel one on the vehicle bus and channel two on the K-TC segment, or REBEL CT or REBEL LT.