REXGEN 2 IMU GNSS keeps the data before and after a trigger, from a J1939 DM1 code or an IMU threshold, with two CAN FD channels, a 6-axis IMU and GNSS on one clock.

In the customer's words

  • By installing the REXGEN we were able to log simultaneously the vibrations of the ship with the internal accelerometer and the CAN bus.

    Kwant ControlsSystem Engineer

  • 2 CAN FD channels
  • 6-axis IMU on the same clock
  • 18 Hz Maximum GNSS update rate

The event capture setup

Read the detail

A fault code, a brake event, an impact or a rare malfunction is only explicable with the seconds before and after it, and with the vehicle's motion and position at that moment. On haul trucks, rolling stock, ships and aircraft the device also has to survive the environment and run unattended.

REXGEN 2 IMU GNSS records two CAN FD channels with a 6-axis IMU and GNSS at up to 18 Hz on one clock. Triggers on bus events such as J1939 DM1 or on IMU thresholds capture pre and post-event windows. Non-removable eMMC, power-safe logging, IP65. Data comes off by USB into REXDESK or, where the asset is remote, the same job runs on REXGEN Air.

  1. 01Fit

    Two CAN FD channels, a 6-axis IMU and GNSS on one clock

  2. 02Trigger

    A bus event or an IMU threshold keeps the seconds before and after

  3. 03Collect

    The data comes off by USB into REXDESK

The hardware

  • Motion & location data logging

    REXGEN 2 IMU GNSS

    From £849 ex VAT £1,018.80 inc VAT
  • CAN to cloud

    REXGEN Air

    From £1,049 ex VAT £1,258.80 inc VAT

Related pages

REXGEN 2 IMU GNSS

Aviation

An in‑flight recorder

Customers fitted REXGEN 2 IMU to light multi-role aircraft as an in-flight recorder on the CANaerospace protocol, logging altitude, airspeed, fuel, engine speed, manifold pressure and temperatures with the IMU flight path. REXDESK decodes CANaerospace.

CAN bus errors: how the bus finds and contains them

Read more

CAN bus errors: how the bus finds and contains them

How the bus catches a bad message five different ways, and how error counters quietly take a failing node off the wire before it...

Questions engineers ask

Question not answered?

Ask an engineer

Can the logger keep the data from before the trigger?

Yes. Triggers capture pre and post-event windows.

What can start a capture?

Bus events such as J1939 DM1, or IMU thresholds.

What does REXGEN 2 IMU GNSS record?

Two CAN FD channels with a 6-axis IMU and GNSS at up to 18 Hz, all on one clock.

Can REXDESK decode CANaerospace?

Yes. REXDESK decodes CANaerospace.

What if the asset is remote?

Data comes off by USB into REXDESK or, where the asset is remote, the same job runs on REXGEN Air.