REXGEN AirSpecification

REXGEN Air: technical specifications

Updated

Check any REXGEN Air figure before you design an installation: networks, inputs, positioning, LTE, storage, security, electrical limits and physical data.

The same figures are in the spec sheet: Download the REXGEN Air spec sheet (PDF, 55 KB).

Dimensions and device elements

Dimension drawing of REXGEN Air in three views: 100 mm long and 65 mm wide, 109.5 mm long over the antenna ports and 30 mm high
Dimensions in millimetres. Allow extra length for the antenna cables at the front and the Mini50 plug at the back.
Front, rear and top views of REXGEN Air with numbered call-outs 1 to 10 for the LEDs, Micro USB port, antenna ports, SIM slot, mounting holes and Molex connector
The numbers match the elements table.
Logger elements
Number Element
1 to 4 Status LEDs 1 to 4
5 Micro USB connector
6 FAKRA Code C connector (blue) for the GNSS antenna
7 SIM slot, behind a lid
8 FAKRA Code D connector (Bordeaux) for the LTE antenna
9 Mounting holes (four)
10 Molex Mini50 dual-row 24-way connector

Networks and protocols

CAN, CAN FD and LIN
Function REXGEN Air
CAN and CAN FD 2 or 4 buses, depending on the model. CAN to ISO 11898-1 up to 1 Mbit/s. ISO and Bosch CAN FD up to 8 Mbit/s. CAN 2.0 parts A and B.
Physical layer Meets ISO 11898-2:2016 and ISO 11898-5:2007
Identifiers 11-bit (CAN 2.0A) and 29-bit (CAN 2.0B)
Throughput Up to 20,000 messages per second
Bit rate Auto-detected or set manually. Bit timing selectable.
Error frames Logs bit-stuffing, form, CRC, bit and acknowledgement errors
Retransmission Configurable retransmission of frames that lost arbitration or were disturbed by errors
Prescaling Record by time (every X ms) or by data (when a chosen byte changes)
Filters Up to 200 standard or extended ID filters per channel (range and acceptance). J1939 source address, destination address and PGN filters.
Triggers CAN ID, CAN signal, digital input and J1939 DM1 counter
Transmit Periodic transmit lists per channel, for example OBD-II requests, with message linking
Silent mode Configurable listen-only mode
DBC Supported for decoding and transmit
LIN 1 bus, master or slave mode, publisher or subscriber. LIN 1.3, 2.0, 2.1 and SAE J2602. Custom frame lengths.
Parallel recording Up to 4 CAN buses and the LIN bus at the same time
Protocols Raw CAN and CAN FD, LIN, SAE J1939 (including DM1), FMS, CANopen, NMEA 2000, OBD-II and UDS (service 0x22)

Inputs and outputs

Analogue and digital inputs
Function REXGEN Air
Analogue inputs 2 bipolar single-ended inputs, ±10 V, 12-bit, up to 1 kHz, input impedance over 50 kΩ
Analogue safe applied voltage ±28 V
Digital inputs 2 unipolar single-ended inputs. Low below 0.8 V, high above 2.5 V, up to 28 V
Digital safe applied voltage ±28 V
Relay driver 1 power stage relay driver output, optional
Instrumentation supply 5 V for external sensors, 100 mA maximum

GNSS and IMU

Positioning and motion sensors
Function REXGEN Air
GNSS module u-blox M8U, 30 Hz, with dead reckoning and geofencing. Some units have the u-blox M8Q, 18 Hz, which supports neither.
Receiver 72-channel: GPS L1C/A, SBAS L1C/A, QZSS L1C/A and L1-SAIF, GLONASS L1OF, BeiDou B1I, Galileo E1B/C
Position accuracy 2.0 m CEP (circular error probable)
Velocity and heading accuracy 0.05 m/s and 0.3°
Sensitivity Tracking and navigation -167 dBm. Cold start -148 dBm.
Acquisition Cold start 26 s. Reacquisition 2 s.
GNSS antenna External active antenna, 3 V supply, FAKRA Code C
IMU 6-axis, logged at up to 1 kHz
Accelerometer range ±2, ±4, ±8 or ±16 g full scale
Gyroscope range ±125, ±250, ±500, ±1000 or ±2000 dps full scale

LTE and cloud

Modem and upload
Function REXGEN Air
Modem LTE Cat 1. Tell us the region of use when you order.
LTE FDD bands 1 (2100 MHz), 2 (1900 MHz), 3 (1800 MHz), 4 (1700 MHz), 7 (2600 MHz), 8 (900 MHz), 12 (700 MHz), 13 (700 MHz), 19 (850 MHz), 20 (800 MHz), 28 (700 MHz)
Receiver sensitivity -98 dBm to -114 dBm, 700 MHz to 2100 MHz
LTE antenna External antenna, FAKRA Code D
Antennas supplied GNSS and LTE antennas with 3 m cables included
SIM Standard SIM, behind the front face
Upload destinations Amazon S3, S3-compatible storage, FTPS servers and the managed web app
Protocols FTP, FTPS, HTTP and HTTPS. Data and over-the-air updates can travel over HTTPS (TLS 1.2).
FTPS Encrypts the log-in. Data channel encryption (PROT P) is not supported, so files travel unencrypted.
Over the air Configuration and firmware over the air (COTA and FOTA), signed. Configurable sync rate. Can be disabled.
Heartbeat Status file to the server and upload state reporting. Optional CAN heartbeat frame with device information, status, storage used, RTC time and configuration details.
Snapshot Decodes chosen CAN signals and sends them to the server periodically
Access control Access rights across loggers and users through S3 policies (AWS upload). S3 credentials can be stored encrypted in the configuration on the logger.

Storage, software and security

Storage, software and security
Function REXGEN Air
Storage 16 or 32 GB eMMC, soldered in and not removable
Cyclic logging FIFO, enabled by default. Once the eMMC is full, the oldest data makes way for new data.
Data integrity FIFO and partitioning keep the most recent data safe
File split By size (10 to 500 MB) and by time period
Device ID Globally unique, so every log file name is unique
Real-time clock Battery-backed, with 10 µs timestamp resolution. Local time zone configurable (default UTC). Synchronised from the LTE network time or from a CAN message, such as the internal GNSS time.
File formats Native RXD and RXE. Export to ASAM MDF4, CSV, MATLAB, ASC, BLF and TRC. Parquet through the cloud conversion function.
Software REXDESK configuration software (free), API and command line interface. REXLIBRARY file conversion library, with source on GitHub. AWS Lambda example application for conversion in the cloud.
Security Signed firmware, device locking and SHA
Firmware Free updates that add features
Status LEDs 4
PC interface Micro USB 2.0 as standard. USB through the Mini50 connector as a factory option.

The USB connection through the Mini50 connector needs a hardware change. Ask for it when you order. Otherwise, the logger must go back to Influx Technology for the change.

Electrical data

Operating voltages
Bus or signal Operating voltage
Power supply (Molex connector) +5 V to +27 V
Power supply (USB) +4.5 V to +5.5 V
CAN and CAN FD +2 V to +3 V
LIN 0 V to +24 V
Digital inputs 0 V to +28 V
Analogue inputs ±10 V
Protection and power
Function REXGEN Air
CAN transceiver protection Bus fault protection ±58 V, thermal shutdown, common mode input ±12 V, TXD dominant timeout and under-voltage protection
LIN transceiver protection ±8 kV HBM and ±2 kV CDM ESD, bus fault protection and TXD dominant timeout
Supply protection Reverse voltage protection, lost if the housing is grounded externally
Running current Under 120 mA at 12 V without cloud upload. Under 300 mA with cloud upload.
Sleep current Under 21 mA in sleep. Under 10 mA in deep sleep.
Power saving Wake on CAN, wake on movement, power down and sleep modes

Physical and environment

Physical data
Function REXGEN Air
Dimensions 100 × 65 × 30 mm (L × W × H). 109.5 mm long over the antenna ports.
Weight 112 g
Enclosure PC and ABS, stackable
Mounting 4 mounting holes, screws supplied
Connector Molex Mini50 dual-row 24-way
Protection rating IP50. Cover the logger where water may get in.
Operating temperature -40 °C to +85 °C
Humidity Up to 90%
Warranty 12 months, with support during the warranty period
Origin Designed and tested in the United Kingdom

Next: REXGEN Air quick start guide.