REXDESK: sleep and wake settings

Updated

Set when a REXGEN logger goes to sleep, how deeply it sleeps and what wakes it again. The logger can then stay fitted to a parked vehicle without draining the battery.

Open the sleep settings

A REXGEN logger goes to sleep when CAN 0 and CAN 1 have both been quiet for the time you set. While it sleeps it draws a fraction of its logging current and records nothing.

  1. Open the configuration. Load or build the configuration for the logger in REXDESK.
  2. Open the sleep settings. In the Device Configuration panel, select Sleep.
  3. Choose a sleep mode. Select No Sleep, Deep Sleep or Normal Sleep in the Sleep mode list.
    The Sleep settings in REXDESK with the Sleep mode list open, showing No Sleep, Deep Sleep and Normal Sleep.
    The Sleep mode list. The wake options below it change with the mode you choose.
  4. Set the delay. In Sleep after no CAN activity for (minutes), enter how long both CAN buses must be quiet before the logger sleeps.
  5. Choose the wake sources. Tick the wake options you need. They are described below.
  6. Send the configuration. Select Run to write the configuration to the logger.

Choose a sleep mode

No Sleep
The logger does not use the sleep and wake function at all.
Deep Sleep
The lowest current. The logger always wakes on activity on CAN 0 or CAN 1, so the CAN and alarm boxes are greyed out. You can add Wake Up On Movement on loggers that support it. Connecting USB does not wake it.
Normal Sleep
A higher current than Deep Sleep, with more ways to wake. The logger always wakes when you connect USB. It also wakes on each source you tick: CAN 0, CAN 1, the alarm or movement.
What wakes the logger in each sleep mode
Wake source Deep Sleep Normal Sleep
USB connected No Yes
Activity on CAN 0 Yes, always When ticked
Activity on CAN 1 Yes, always When ticked
Alarm No When ticked
Movement When ticked When ticked
Sleep modes and what wakes the logger REXDESK · SLEEP AND WAKE Sleep modes and what wakes the logger Logging resting state No Sleep: stays in Logging When CAN 0 and CAN 1 are both quiet for Sleep after no CAN activity for (minutes), it goes to the mode set in Sleep mode Normal Sleep more ways to wake Deep Sleep lowest current wake wake Wakes on USB connected Activity on CAN 0 Activity on CAN 1 Alarm once, every day or minutes after sleep Movement (loggers with an IMU) Wakes on USB connected Activity on CAN 0 Activity on CAN 1 Alarm Movement (loggers with an IMU) always when ticked in REXDESK never Current draw and the wake sources each logger supports differ: see the table in this guide.

Wake options in Normal Sleep

Normal Sleep selected, with a 2 minute delay and check boxes for Wake Up On CAN 0, Wake Up On CAN 1, Wake Up On Alarm and Wake Up On Movement.
Normal Sleep with its four wake options.

Wake on CAN

Wake Up On CAN 0
The logger wakes when there is traffic on the CAN 0 bus.
Wake Up On CAN 1
The logger wakes when there is traffic on the CAN 1 bus.

Tick both to wake on either bus.

Wake on alarm

Tick Wake Up On Alarm to wake the logger by its own clock, then choose one of three timings:

Wake up once
Wakes once, on the date and at the time you set in Alarm Date and Time.
Wake up every day
Wakes at the same time every day.
Wake up minutes after sleep
Wakes the number of minutes you enter after it goes to sleep.
Wake Up On Alarm ticked with Wake up once selected and a calendar open to pick the alarm date and time.
Wake up once uses the date and time picker.

Wake on movement

Tick Wake Up On Movement to wake the logger as soon as its motion sensor detects movement. It needs a logger with a built-in IMU. See the table below.

Watch: Set up Sleep mode in a REXGEN data logger (1:30)

Current and wake sources by logger

The figures are the published figures for each logger. Use Deep Sleep when a logger stays on a vehicle battery for days.

Typical current at 12 V and wake sources, by logger
Logger Logging Normal Sleep Deep Sleep Wakes on
REXGEN 1 87 mA Under 17 mA Under 2 mA CAN
REXGEN 2 Under 75 mA Under 17 mA Under 2 mA CAN
REXGEN 2 IMU GNSS Under 80 mA Under 25 mA Under 2 mA CAN, movement
REXGEN Air Under 120 mA, under 300 mA while uploading Under 21 mA Under 10 mA CAN, movement
REXGEN Pro Under 200 mA Under 15 mA Not published CAN, movement, digital input

The table lists the wake sources published on the product pages. The alarm is not among them, but REXDESK offers it in the sleep settings.

REXGEN Pro also wakes on a digital input. The REXDESK sleep settings shown here have no option for it.

Before a logger is left asleep

  • The delay restarts with every CAN message on either bus, so the logger sleeps only after a full quiet period.
  • On a REXGEN Air or REXGEN Pro that uploads to the cloud, tick Upload All Files Before Sleep in the upload settings. Every file then reaches the server before the logger sleeps. See REXDESK: upload logs to AWS S3, MinIO or Google Cloud Storage.
  • Deep Sleep does not wake on USB. To connect a sleeping logger to REXDESK, wake it with CAN traffic first.

Next: REXDESK: upload logs to AWS S3, MinIO or Google Cloud Storage.

Products in this guide

REXDESK

Logger setup & data export

View REXDESK Ask an engineer

REXGEN 1

Vehicle black box

View REXGEN 1 Ask an engineer

REXGEN 2

Evidence data logger

View REXGEN 2 Ask an engineer

REXGEN 2 IMU GNSS

Motion & location data logging

View REXGEN 2 IMU GNSS Ask an engineer

REXGEN Air

CAN to cloud

View REXGEN Air Ask an engineer

REXGEN Pro

Edge data platform

View REXGEN Pro Ask an engineer

Still stuck?

Our engineers answer support questions on every Influx Technology product.