REBEL CTREBEL LTPinout
REBEL breakout cables: INF4203 and INF4204.1 multi-connect pinouts
Find out which REBEL breakout cable you have and wire each of its leads. The leads carry CAN, power, LIN, the analogue and digital channels and the auxiliary power output for instrumentation modules.
Which cable you need
Both cables plug into the logger's 25-way OBD and INST connector. They break it out to standard 9-way D-Subs wired to CiA 303-1, so CAN devices and interfaces plug straight in.
| Part | Name | Supplied with | Leads |
|---|---|---|---|
INF4203 |
Two CAN breakout cable | REBEL LT | CAN0/PWR/K-Line and AUX/CAN1 |
INF4204.1 |
Multi-connect cable, 5 lead | REBEL CT | CAN0/PWR, AUX/CAN1, CAN2/LIN0, CAN3/LIN1 and Dig/An |
To use the analogue and digital channels on REBEL LT, you also need the INF4204.1. Only its Dig/An lead carries them. On REBEL LT the CAN2/LIN0 and CAN3/LIN1 leads carry no bus, because the logger has no CAN 2, CAN 3 or LIN.
INF4203 two CAN breakout cable

| Item | Value |
|---|---|
| Length | 230 mm |
| Wire | 24 AWG, 0.5 mm |
| Connector A | 25-way D-Sub socket, to the logger |
| Connector B | 9-way D-Sub plug with nuts, CAN 0, power and K-Line |
| Connector C | 9-way D-Sub socket, CAN 1 and auxiliary power output |
| Operating temperature | -20 to +80 °C |
| Weight | 142 g |
CAN0/PWR/K-Line lead
This lead is a male 9-way D-Sub with nuts. It powers the logger and connects CAN 0 and the K-Line.
| Pin | Signal |
|---|---|
| 2 | CAN-L, CAN 0 (high-speed bus) |
| 3 | Ground |
| 4 | K-Line (ISO 9141) |
| 5 | Power ground |
| 7 | CAN-H, CAN 0 (high-speed bus) |
| 9 | Supply, 4.5 to 36 V DC |
Pins 1, 6 and 8 are not connected.
AUX/CAN1 lead
This lead is a female 9-way D-Sub with screws. It connects CAN 1, and its auxiliary power output can power an instrumentation module.
| Pin | Signal |
|---|---|
| 2 | CAN-L, CAN 1 (medium-speed bus) |
| 3 | Ground |
| 5 | Ground |
| 6 | Digital I/O 0. As an output, 50 mA maximum |
| 7 | CAN-H, CAN 1 (medium-speed bus) |
| 9 | Auxiliary power output |
Pins 1, 4 and 8 are not connected.
Logger end
This end is a female 25-way D-Sub with screws. The table lists the logger pins that the cable carries, taken from the REBEL LT connector table.
| Pin | Signal | Lead |
|---|---|---|
| 6 | CAN-L, CAN 1 | AUX/CAN1 pin 2 |
| 7 | CAN-L, CAN 0 | CAN0/PWR/K-Line pin 2 |
| 8 | K-Line | CAN0/PWR/K-Line pin 4 |
| 9 | Supply, 4.5 to 36 V DC | CAN0/PWR/K-Line pin 9 |
| 12 | Digital I/O 0 | AUX/CAN1 pin 6 |
| 19 | CAN-H, CAN 1 | AUX/CAN1 pin 7 |
| 20 | CAN-H, CAN 0 | CAN0/PWR/K-Line pin 7 |
| 21 | Ground | Both leads |
| 22 | Power ground | Both leads |
| 23 | Digital I/O 3 or auxiliary power output +Vd | AUX/CAN1 pin 9 |
Some older documents describe connector C as carrying CAN 1 and LIN. REBEL LT has no LIN. Connector C carries CAN 1 and the auxiliary power output.
INF4204.1 multi-connect cable

| Item | Value |
|---|---|
| Length | 230 mm |
| Wire | 24 AWG, 0.5 mm |
| Connector A | 25-way D-Sub socket, to the logger |
| Connector B | 9-way D-Sub plug with nuts, CAN0/PWR |
| Connector C | 9-way D-Sub socket, AUX/CAN1 |
| Connector D | 9-way D-Sub socket, CAN2/LIN0 |
| Connector E | 9-way D-Sub socket, CAN3/LIN1 |
| Connector F | 15-way D-Sub socket, Dig/An (digital and analogue) |
| Operating temperature | -20 to +80 °C |
| Weight | 263 g |
CAN0/PWR lead
This lead is a male 9-way D-Sub with nuts. It powers the logger and connects CAN 0.
| Pin | Signal |
|---|---|
| 2 | CAN-L, CAN 0 (high-speed bus) |
| 3 | Ground |
| 4 | K-Line, REBEL LT only |
| 5 | Power ground |
| 7 | CAN-H, CAN 0 (high-speed bus) |
| 9 | Supply, 4.5 to 36 V DC |
Pins 1, 6 and 8 are not connected. An earlier revision of the cable carried CAN 1 on pins 1 and 8 of this lead.
AUX/CAN1 lead
This lead is a female 9-way D-Sub with screws. It connects CAN 1 and carries the auxiliary power output, which can power an instrumentation module such as a K-BOX.
| Pin | Signal |
|---|---|
| 2 | CAN-L, CAN 1 (medium-speed bus) |
| 3 | Ground |
| 5 | Power ground |
| 7 | CAN-H, CAN 1 (medium-speed bus) |
| 9 | Auxiliary power output |
CAN2/LIN0 lead
This lead is a female 9-way D-Sub with screws. On REBEL CT it connects CAN 2 (CAN 2.0 or CAN FD) and LIN 0.
| Pin | Signal |
|---|---|
| 1 | LIN 0 |
| 2 | CAN-L, CAN 2 (CAN 2.0 or CAN FD) |
| 3 | Ground |
| 5 | Power ground |
| 7 | CAN-H, CAN 2 (CAN 2.0 or CAN FD) |
| 9 | Digital I/O 3 or auxiliary power output +Vd |
CAN3/LIN1 lead
This lead is a female 9-way D-Sub with screws. On REBEL CT it connects CAN 3 (CAN 2.0 or CAN FD) and LIN 1.
| Pin | Signal |
|---|---|
| 1 | LIN 1 |
| 2 | CAN-L, CAN 3 (CAN 2.0 or CAN FD) |
| 3 | Ground |
| 5 | Power ground |
| 7 | CAN-H, CAN 3 (CAN 2.0 or CAN FD) |
| 9 | Digital I/O 3 or auxiliary power output +Vd |
If you wire an input to Digital I/O 3 on pin 9 of either lead, keep it within 0 to +12 V.
Dig/An lead
This lead is a female 15-way D-Sub. It carries the four analogue inputs, three digital I/O channels, the +4.5 V instrumentation supply and the wake-up pin.
| Pin | Signal | Notes |
|---|---|---|
| 2 | Digital I/O 1 | Input or output |
| 3 | +4.5 V instrumentation supply | 100 mA maximum |
| 4 | Ground | Signal ground |
| 6 | Analogue ground | Reference for the analogue inputs |
| 7 | Analogue input 1 | Keep within -10 to +10 V |
| 8 | Analogue input 3 | Keep within -10 to +10 V |
| 9 | Digital I/O 0 | Input or output |
| 10 | Digital I/O 2 | Input or output |
| 11 | Ground | Signal ground |
| 13 | Wake-up | Pull to ground for more than 20 ms to wake the logger |
| 14 | Analogue input 0 | Keep within -10 to +10 V |
| 15 | Analogue input 2 | Keep within -10 to +10 V |
Pins 1, 5 and 12 are not connected. For the digital I/O limits, see REBEL and K-Series: wiring the wake-up pin and digital I/O.
Logger end
This end is a female 25-way D-Sub with screws. Its pins match the logger's OBD and INST connector one for one. Logger pin 8 carries the K-Line on REBEL LT only. For the logger pinouts, see these guides.
Power a K-Series module from AUX/CAN1
A REBEL logger can switch power to one instrumentation module on its AUX/CAN1 lead, so the module sleeps and wakes with the logger.
- Connect the module. Plug the module's CAN input into the AUX/CAN1 lead.
- Open the configuration properties. In DIALOG, right-click the project and select Properties.
-
Enable auxiliary power. In the Edit Configuration window, select the Settings tab. Tick Aux Power On, then select OK.

The Settings tab also holds the Keep Alive times. - Send the configuration. Right-click the project and select Send Configuration to the Logger.
The auxiliary power output follows the logger's own supply. Before you connect a module, check that your supply is inside its range. K-TC takes 4.5 to 31 V. K-BOX and K-AN8 take 6 to 36 V. Every further module in a daisy chain needs an external supply. See K-Series: connecting and powering modules.
INF4213 screw terminal
INF4213 is a 15-way D-Sub plug with screw terminals. It fits the Dig/An lead of the INF4204.1, so you can wire sensors and switches without soldering a connector. It is male with 15 pins, weighs 45 g and works from -20 to +80 °C.
INF4302 digital switch
INF4302 is a push switch on a cable. Use it to mark events in a log by hand. It plugs into the Dig/An lead of the INF4204.1 and pulls Digital I/O 0 to ground while you press it. The switch resets itself when you release it.
| Pin | Wire |
|---|---|
| 4 | Cable shields |
| 9 | Switch S1, light blue wire (Digital I/O 0 on the Dig/An lead) |
| 11 | Switch S1, black wire (ground on the Dig/An lead) |
The cable is 1800 mm long with 26 AWG (0.4 mm) wire. It weighs 116 g and works from -20 to +80 °C. To record the marks, set Digital I/O 0 as an input in the configuration.
Next: REBEL and K-Series: wiring the wake-up pin and digital I/O.