K-AN8K-BOXREBEL CTREBEL LTPinout
REBEL and K-Series: wiring the wake-up pin and digital I/O
Wake a REBEL logger from sleep with an external switch, transistor or relay. Wire the digital inputs and outputs of REBEL, K-BOX and K-AN8 without exceeding their limits.
Where the pins are
The wake-up pin is on REBEL loggers only. K-BOX and K-AN8 have digital channels but no wake-up input.
| Function | REBEL OBD and INST, 25-way | INF4204.1 Dig/An lead, 15-way | K-BOX and K-AN8 CAN connectors, 9-way |
|---|---|---|---|
| Wake-up | Pin 5 | Pin 13 | None |
| Digital I/O 0 | Pin 12 | Pin 9 | None |
| Digital I/O 1 | Pin 24 | Pin 2 | Pin 4 |
| Digital I/O 2 | Pin 11 | Pin 10 | Pin 8 |
| Digital I/O 3 | Pin 23, also the auxiliary power output +Vd | None | Pin 6 |
| Digital output 4 | None | None | Pin 1, or the +4.5 V supply |
| +4.5 V instrumentation supply | Pin 10 | Pin 3 | Pin 1, optional |
| Ground | Pins 21 and 22 | Pins 4 and 11 | Pins 3 and 5 |
For the full pinouts, see these guides.
- REBEL LT: connector pinouts
- REBEL CT: connector pinouts
- K-BOX: connector pinouts
- K-AN8: connector pinouts
Wake a REBEL logger with the wake-up pin
The wake-up pin is held high inside the logger. To wake the logger from sleep, switch the pin to power ground for longer than 20 ms. Use one of three circuits:
- Switch. A push button or contact between the wake-up pin and power ground.
- Transistor. An NPN transistor with its collector on the wake-up pin and its emitter on power ground. Your control signal switches it on through a base resistor.
- Relay. A relay contact between the wake-up pin and power ground, with the coil driven by a separate circuit.
Once awake, the logger stays awake while a CAN bus is active, then goes back to sleep after the delay set in its configuration. For the power states, see REBEL LT and REBEL CT: overview and software.
Wire a digital input
As an input, a digital pin reads low or high against fixed thresholds (see the limits below). Pull the input up to the +4.5 V instrumentation supply through a 1 kΩ resistor. Then pull it low with one of these:
- A switch to power ground
- An NPN transistor to power ground, driven by your control signal
- A relay contact to power ground
- A Schmitt trigger buffer such as the SN74LVC1G14, which drives the input directly
On K-BOX and K-AN8, three of the four digital channels also work as frequency, counter or pulse inputs. They work up to 100 kHz, with a minimum pulse of 100 ns.
Drive a load from a digital output
As an output, a digital pin is an open collector. It switches the load's return to ground. The load takes its positive supply from elsewhere.
REBEL outputs
There are five ways to use a REBEL output:
- Logic input. Pull the output up to +4.5 V instrumentation through 1 kΩ and feed a Schmitt trigger buffer.
- LED from +4.5 V. Connect an LED and a 210 Ω resistor in series from +4.5 V instrumentation to the output.
- LED from +12 V. Connect an LED and a 1 kΩ resistor in series from +12 V to the output.
- Relay. Connect a relay coil from +12 V to the output, with a series resistor to keep the current inside the output limit.
- Transistor. Pull the output up to +4.5 V through 1 kΩ. Use it to drive the base of an NPN transistor that switches a larger load.
K-BOX and K-AN8 outputs
K-BOX and K-AN8 have four open-collector outputs rated 45 V and 10 mA. They switch relays, indicators and logic inputs. Drive bigger loads through a relay, with a flyback diode across the coil.
Limits for REBEL LT and REBEL CT
Earlier documentation gives two sets of figures. The table uses the REBEL LT specification for both loggers.
| Item | Limit |
|---|---|
| Wake-up pin | Held high inside the logger. Pull to ground for more than 20 ms to wake. |
| Input low | Below 2 V |
| Input high | Above 2.5 V |
| Input voltage | Up to 36 V absolute maximum, -0.5 V minimum. Keep inputs within 0 to +12 V. |
| Output type | Open collector, collector-emitter voltage 36 V, saturation voltage below 0.6 V |
| Output current | 50 mA maximum |
| +4.5 V instrumentation supply | 100 mA maximum |
Limits for K-BOX and K-AN8
| Item | Limit |
|---|---|
| Digital channels | 4, each an input or an output |
| Input low | Below 1.5 V |
| Input high | Above 2.0 V |
| Input voltage | -8 to +12 V |
| Frequency inputs | 3 channels, up to 100 kHz, minimum pulse 100 ns |
| Outputs | 4 open-collector outputs, 45 V and 10 mA maximum |
| +4.5 V option on pin 1 | Available instead of digital output 4 |
These outputs switch a relay. They are not relay contacts themselves.
Safety
Next: DIALOG: what it does, versions and system requirements.
Products in this guide
Still stuck?
Our engineers answer support questions on every Influx Technology product.