GeneralPinout
REXGEN OEM: pinouts and multiconnect cables
Find the pin of every REXGEN OEM signal on the logger connector and the 25-way D-Sub breakout. This guide also covers each lead of the 2-way and 5-way multi-connect cables.
How the cables fit together
REXGEN OEM has one JAE compact automotive 34-way connector. A breakout cable turns it into a female 25-way D-Sub connector and an RJ45 Ethernet socket. The multi-connect cables split the 25-way D-Sub into separate D-Sub leads. The breakout and both multi-connect cables are sold separately.

JAE 34-pin connector
The connector and its pin assignment are the same as on REXGEN Pro.
| Pin | Signal | Description |
|---|---|---|
| 1 | PwrVihOut |
Power output, voltage input high |
| 2 | GND |
Ground |
| 3 | Lin0 |
LIN 0 |
| 4 | DigRelayOut |
Open-collector output for a relay or indicator, optional |
| 5 | DigPwmIn1 |
Digital input 1, PWM |
| 6 | Erase# |
Erase pin |
| 7 | PwrOut0 |
Power output 0 |
| 8 | PwrOutGND |
Power output ground |
| 9 | AdcIn0 |
Analogue input 0 |
| 10 | GNDa |
Analogue ground |
| 11 | Can0-L |
CAN 0 low |
| 12 | Can1-L |
CAN 1 low |
| 13 | Can2-L |
CAN 2 low |
| 14 | Can3-L |
CAN 3 low |
| 15 | TrD2_P |
Ethernet receive + (D2) |
| 16 | TrD2_N |
Ethernet receive − (D2) |
| 17 | TrD1_P |
Ethernet transmit + (D1) |
| 18 | 6.5-27V |
Supply, 6.5 V to 27 V |
| 19 | PowerGND |
Power ground |
| 20 | Lin1 |
LIN 1 |
| 21 | DigIn3 |
Digital input 3 |
| 22 | DigIn2 |
Digital input 2 |
| 23 | DigPwmIn0 |
Digital input 0, PWM |
| 24 | Clamp-15 |
Clamp-15 (ignition) input |
| 25 | PwrOut1 |
Power output 1 |
| 26 | AdcIn1 |
Analogue input 1 |
| 27 | AdcIn2 |
Analogue input 2 |
| 28 | Can0-H |
CAN 0 high |
| 29 | Can1-H |
CAN 1 high |
| 30 | Can2-H |
CAN 2 high |
| 31 | Can3-H |
CAN 3 high |
| 32 | NfcAntN |
NFC antenna − |
| 33 | NfcAntP |
NFC antenna + |
| 34 | TrD1_N |
Ethernet transmit − (D1) |
D-Sub 25 breakout
| Pin | Signal | Description |
|---|---|---|
| 1 | Ain3_inst |
Not connected |
| 2 | LIN2 |
LIN 2 |
| 3 | Can3-L |
CAN 3 low |
| 4 | Ain1_inst |
Analogue input 1 |
| 5 | Wake-up# |
Not connected |
| 6 | Can1-L |
CAN 1 low |
| 7 | Can0-L |
CAN 0 low |
| 8 | LIN1 |
Not connected |
| 9 | 6.5-27V |
Supply, 6.5 V to 27 V |
| 10 | +4.5inst |
+4.5 V instrumentation supply, draw no more than 100 mA |
| 11 | Dig2 |
Digital input 2 |
| 12 | Dig0 |
Digital input 0 |
| 13 | Can2-L |
CAN 2 low |
| 14 | Ain2_ins |
Analogue input 2 |
| 15 | LIN1 |
LIN 1 |
| 16 | Can3-H |
CAN 3 high |
| 17 | Ain0_inst |
Analogue input 0 |
| 18 | GndA |
Analogue ground |
| 19 | Can1-H |
CAN 1 high |
| 20 | Can0-H |
CAN 0 high |
| 21 | GND |
Ground |
| 22 | PowerGND |
Power ground |
| 23 | +Vd |
Positive drain voltage |
| 24 | Dig1 |
Digital input 1 |
| 25 | Can2-H |
CAN 2 high |
RJ45 Ethernet
| Pin | Signal | Wire colour |
|---|---|---|
| 1 | Transmit + (D1) | White with orange stripe |
| 2 | Transmit − (D1) | Orange with white stripe, or solid orange |
| 3 | Receive + (D2) | White with green stripe |
| 6 | Receive − (D2) | Green with white stripe, or solid green |
Pins 4, 5, 7 and 8 are not connected.
2-way multiconnect cable
This cable splits a female 25-way D-Sub with screws into two 9-way D-Sub leads.

| Pin | Function |
|---|---|
| 2 | CAN 0 low |
| 3 | Signal ground |
| 4 | K-Line |
| 5 | Power ground |
| 7 | CAN 0 high |
| 9 | Supply voltage |
| Pin | Function |
|---|---|
| 2 | CAN 1 low |
| 3 | Signal ground |
| 5 | Power ground |
| 6 | Digital input/output 0 |
| 7 | CAN 1 high |
| 9 | Switched power supply, digital input/output 3 |
5-way multiconnect cable
This cable splits a female 25-way D-Sub with screws into four 9-way D-Sub leads and one 15-way D-Sub lead. Each lead has a coloured label.

| Pin | Function |
|---|---|
| 1 | CAN 1 low |
| 2 | CAN 0 low |
| 3 | Signal ground |
| 4 | K-Line |
| 5 | Power ground |
| 7 | CAN 0 high |
| 8 | CAN 1 high |
| 9 | Supply voltage |
| Pin | Function |
|---|---|
| 2 | CAN 1 low |
| 3 | Signal ground |
| 5 | Power ground |
| 7 | CAN 1 high |
| 9 | Switched power supply, digital input/output 3 |
| Pin | Function |
|---|---|
| 2 | Digital input/output 1, 0 V to +12 V as an input |
| 3 | +4.5 V instrumentation supply, draw no more than 100 mA |
| 4 | Ground |
| 6 | Analogue ground |
| 7 | Analogue input 1, -10 V to +10 V |
| 8 | Analogue input 3, -10 V to +10 V |
| 9 | Digital input/output 0, 0 V to +12 V as an input |
| 10 | Digital input/output 2, 0 V to +12 V as an input |
| 11 | Ground |
| 13 | Wake-up pin |
| 14 | Analogue input 0, -10 V to +10 V |
| 15 | Analogue input 2, -10 V to +10 V |
The Dig/An lead is a 15-way D-Sub.
| Pin | Function |
|---|---|
| 1 | LIN 0 |
| 2 | CAN 2 low |
| 3 | Signal ground |
| 5 | Power ground |
| 7 | CAN 2 high |
| 9 | Switched power supply, digital input/output 3 |
| Pin | Function |
|---|---|
| 1 | LIN 1 |
| 2 | CAN 3 low |
| 3 | Signal ground |
| 5 | Power ground |
| 7 | CAN 3 high |
| 9 | Switched power supply, digital input/output 3 |
For wiring rules, see CAN bus wiring: termination, cable length and grounding.