GeneralDeveloper
REXGEN OEM: read and write data through the data pipes
Read live data from the REXGEN OEM logger on its Linux platform and send CAN and CAN FD frames. You do both through its data pipes.
How the data pipes work
The REXGEN embedded platform inside the logger records the CAN buses, the IMU (accelerometer and gyroscope), the analogue inputs and the digital inputs. A Linux service, rexgen_data.service, makes that data available as pipes under /var/run/rexgen/. You read and write them like ordinary files, from the shell or from your own application.
| Pipe | Direction | Data |
|---|---|---|
/var/run/rexgen/can0/rx to can3/rx
|
Read | Frames received on CAN 0 to CAN 3 |
/var/run/rexgen/can0/tx to can3/tx
|
Write | Frames to send on CAN 0 to CAN 3 |
/var/run/rexgen/acc/rx |
Read | Accelerometer |
/var/run/rexgen/gyro/rx |
Read | Gyroscope |
/var/run/rexgen/adc/rx |
Read | Analogue inputs |
/var/run/rexgen/dig/rx |
Read | Digital inputs |
Start and stop the data service with:
systemctl start rexgen_data.service
systemctl stop rexgen_data.service
Demo applications that use the data pipes are in /home/root/rexusb/examples on the device.
Read CAN and CAN FD data
Read a bus with cat or less on its rx pipe:
cat /var/run/rexgen/can0/rx
cat /var/run/rexgen/can1/rx
cat /var/run/rexgen/can2/rx
cat /var/run/rexgen/can3/rx
Each line is one frame, with these fields:
- A timestamp in brackets
- The channel
- The identifier in hex
- The data length in square brackets
- The data bytes in hex
(1698509051) can0 200 [8] FF FF 7F FF 7F FF 88 00
(1698509127) can0 231 [7] 01 52 64 00 04 00 80
(1698510079) can0 201 [8] 00 00 40 00 00 00 FF FF
Send CAN frames
Write a frame to a bus with echo on its tx pipe. This example sends identifier 130 with eight data bytes on CAN 0:
echo "(0) can0 130 [8] 01 02 03 04 05 06 07 08" > /var/run/rexgen/can0/tx
For CAN 1 to CAN 3, write to that channel's pipe and name the same channel in the frame, for example can1 to /var/run/rexgen/can1/tx.
Send CAN FD frames
Add [F] before the identifier to send a CAN FD frame. This example sends identifier 7B3 with 16 data bytes on CAN 0:
echo "(0) can0 [F] 7B3 [16] 01 02 03 04 05 06 07 08 88 99 88 77 66 55 44 33" > /var/run/rexgen/can0/tx
Use the other channels' tx pipes in the same way.
Read the IMU
cat /var/run/rexgen/acc/rx
cat /var/run/rexgen/gyro/rx
Each line carries a timestamp, the axis and the value:
(264397353) Y -0.018056
(264397353) Z -0.980880
(264397675) X 0.240584
The gyroscope pipe uses the same form:
(283906287) X 3.010000
(283906287) Y 2.625000
Read the analogue and digital inputs
cat /var/run/rexgen/adc/rx
cat /var/run/rexgen/dig/rx
Each analogue line carries a timestamp, the input number and the value:
(2261881788) 0 0.007500
(2261881958) 2 0.000000
(2261882196) 1 0.000000
(2261882196) 3 11.542601
In this example, input 3 reads about 11.5. This fits an analogue input connected to the power supply.
Read GNSS data
GNSS data does not use a pipe. Start it with:
/opt/influx/gnssdata_start.sh
The NMEA sentences then arrive on the serial port ttymxc1. Read them with:
cat /dev/ttymxc1
$GPGSA,A,1,,,,,,,,,,,,,,,*32
$GPGGA,,,,,,0,,,,,,,,*66
$GPRMC,,V,,,,,,,,,,N*53
Empty fields like these mean the receiver has no fix yet.
Still stuck?