REXGEN XML reference: triggers, conditions and logic blocks
Make the logger react to what it measures. Compare values, do arithmetic, filter signals and fire triggers that start or stop recording or send a message.
About this guide
The schema, ReXConfig.xsd revision 1.1, defines the logic blocks in this guide. One published example uses ARITHMETIC and CONSTANT.
The quickest way to get a working trigger is to build it in REXDESK. Its Save Project command writes the project as XML that you can compare with this guide. See REXDESK: start and stop logging with triggers.
Every block here takes a UID attribute (required and unique in the file) and the optional Version, X and Y. It sits inside BLOCKS in a list named after it, for example TRIGGER_LIST. Blocks connect by UID. See REXGEN XML configuration: how it fits together.
Triggers and comparisons
TRIGGER
A trigger compares inputs and fires when the condition is met. To start or stop recording, name its UID in a recorder's EnableUID or DisableUID. To send an event message, name it in a message's TriggeringMessageUniqueID. This one fires when the value from block 30 stays above a constant of 3,000 for 500 ms.
<CONSTANT UID="31">
<Value>3000</Value>
</CONSTANT>
<TRIGGER UID="40">
<Name>Engine above 3000 rpm</Name>
<InputUID1>30</InputUID1>
<InputUID2>31</InputUID2>
<OperatorCondition>GREATER</OperatorCondition>
<ConditionAcceptanceTime>500</ConditionAcceptanceTime>
<KeepActiveTime>0</KeepActiveTime>
<DoNotActivateTimeout>0</DoNotActivateTimeout>
</TRIGGER>
Name- A name for the trigger. Required. String.
-
InputUID1,InputUID2 - The two values compared, usually a signal and a constant. Required. Unsigned short.
InputUID3- A third value for range checks. Optional. Unsigned short.
OperatorCondition- The test:
EQUAL,NOT_EQUAL,GREATER,LESS,EQUAL_GREATER,EQUAL_LESS,IN_RANGE,IN_RANGE_INCLUSIVE,NOT_IN_RANGE,NOT_IN_RANGE_INCLUSIVE,NEW,INCREMENT,DECREMENT,CHANGEorSAME. Required. ConditionAcceptanceTime- Time in milliseconds the condition must stay true before the trigger fires. Optional. Unsigned int. Default
0. KeepActiveTime- Time the trigger stays active after it fires. Required. Unsigned int.
DoNotActivateTimeout- Time during which the trigger cannot fire again. Required. Unsigned int.
ImpulseOnTrue- Optional. String. Default
0. MaximumTriggeringCount- Maximum number of times the trigger can fire.
0means no limit. Optional. Unsigned short. Default0. TriggerCountResetUID- UID of the signal that resets the trigger's count. Optional. Unsigned short. Default
0.
CONDITION
A condition takes two inputs, two further condition inputs and an operator from the same list as TRIGGER.
<CONDITION UID="41">
<Input1UID>30</Input1UID>
<Input2UID>31</Input2UID>
<InputConditionUID1>0</InputConditionUID1>
<InputConditionUID2>0</InputConditionUID2>
<OperatorCondition>EQUAL_GREATER</OperatorCondition>
</CONDITION>
-
Input1UID,Input2UID - The values compared. Required. Unsigned short.
-
InputConditionUID1,InputConditionUID2 - Two further inputs whose role is not described. Required. Unsigned short.
OperatorCondition- The test, as for
TRIGGER. Required.
RELATIONAL_OPERATOR
This block compares two values and outputs the result.
<RELATIONAL_OPERATOR UID="42">
<InputUID1>30</InputUID1>
<InputUID2>31</InputUID2>
<RelationalOperator>GREATER</RelationalOperator>
</RELATIONAL_OPERATOR>
-
InputUID1,InputUID2 - The values compared. Required. Unsigned short.
RelationalOperator-
EQUAL,NOT_EQUAL,GREATER,LESS,EQUAL_GREATERorEQUAL_LESS. Required.
Constants and arithmetic
CONSTANT
This block holds a fixed value that other blocks can use.
<CONSTANT UID="200">
<Value>4</Value>
</CONSTANT>
Value- The value. Required. Float.
ARITHMETIC
This block combines two inputs as Input1 operator Input2. The published averaging example sums four thermocouple signals with three SUM blocks. This block then divides the total by a CONSTANT of 4.
<ARITHMETIC UID="1009">
<Input1UID>1007</Input1UID>
<Input2UID>200</Input2UID>
<ArithmeticAction>DIV</ArithmeticAction>
</ARITHMETIC>
-
Input1UID,Input2UID - The two operands. Required. Unsigned short.
ArithmeticAction-
SUM,SUB,MUL,DIVor the bitwiseAND,OR,XORandNOT. Required.
RATIONAL_FORMULA
This block applies the ASAM rational function (A·x² + B·x + C) / (D·x² + E·x + F) to one input, with six parameters.
<RATIONAL_FORMULA UID="43">
<InputUID>30</InputUID>
<ParA>0</ParA>
<ParB>1</ParB>
<ParC>0</ParC>
<ParD>0</ParD>
<ParE>0</ParE>
<ParF>1</ParF>
</RATIONAL_FORMULA>
InputUID- The input value. Required. Unsigned short.
-
ParAtoParF - The six parameters. The values in the example pass the input through unchanged. Required. Float.
Signal processing
SIGNAL_FILTER
This block smooths an input. The example takes a moving average over four samples.
<SIGNAL_FILTER UID="44">
<InputUID>30</InputUID>
<Filter_Type>MOVING_AVERAGE</Filter_Type>
<WindowSize>4</WindowSize>
<Alpha>0</Alpha>
<InitialValue>0</InitialValue>
<Name>Speed smoothed</Name>
</SIGNAL_FILTER>
InputUID- The input value. Required. Unsigned short.
Filter_Type-
MOVING_AVERAGE,MEDIAN,LOW_PASSorHIGH_PASS. Required. DefaultMOVING_AVERAGE. WindowSize- Number of samples for the moving average or median. Required. Unsigned short. Default
4. Alpha- Smoothing factor for the low-pass and high-pass filters. Required. Float.
InitialValue- Starting value of the output. Required. Float. Default
0. Name- Optional. String.
SIGNAL_OPERATOR
This block works on successive samples of one input. The schema gives the formulas, where Ts is the sample period:
-
DIFFERENCE: y[k] = x[k] − x[k−1] -
DERIVATIVE: y[k] = (x[k] − x[k−1]) / Ts -
INTEGRATOR: y[k] = y[k−1] + x[k] × Ts -
ACCUMULATOR: y[k] = y[k−1] + x[k]
<SIGNAL_OPERATOR UID="45">
<InputUID>30</InputUID>
<Operator_Type>DERIVATIVE</Operator_Type>
<InitialValue>0</InitialValue>
<Name>Speed rate of change</Name>
</SIGNAL_OPERATOR>
InputUID- The input value. Required. Unsigned short.
Operator_Type- One of the four operations in the list. Required. Default
DIFFERENCE. InitialValue- Starting value of the output. Required. Float. Default
0. Name- Optional. String.
Counters and switches
COUNTER
This block generates a counting value, for example a rolling counter in a transmitted message.
<COUNTER UID="46">
<CounterType>LOOP</CounterType>
<Cycle>100</Cycle>
<InitialValue>0</InitialValue>
<MaxValue>15</MaxValue>
<Seed>1</Seed>
</COUNTER>
CounterType-
LOOP(start again after the maximum) orSINGLE(stop at it). Optional. Cycle- Counting period in milliseconds. Required. Unsigned short.
-
InitialValue,MaxValue - First and maximum value. Required. Unsigned int.
Seed- The step added each cycle. Required. Unsigned short.
Delay- Optional. Unsigned int.
SWITCH
This block chooses one of several inputs by the value of a selector input, like a multiplexer.
<SWITCH UID="47">
<InputSwitchUID>48</InputSwitchUID>
<InputCount>2</InputCount>
<InputDefaultUID>31</InputDefaultUID>
<CASE_LIST>
<CASE>
<CaseValue>1</CaseValue>
<InputUID>30</InputUID>
</CASE>
<CASE>
<CaseValue>2</CaseValue>
<InputUID>44</InputUID>
</CASE>
</CASE_LIST>
</SWITCH>
InputSwitchUID- The selector. Required. Unsigned short.
InputCount- Number of cases. Required. Unsigned int.
InputDefaultUID- The input used when no case matches. Required. Unsigned short.
CASE_LIST- One
CASEfor each choice. When the selector equalsCaseValue, the output isInputUID. Required.
Start recording with a trigger
-
Build the trigger. Add the
TRIGGERand the blocks it compares, as in the first example. -
Hold recording until it fires. In the
SDINTERFACE, setInitialEnableStatetofalseandEnableUIDto the trigger's UID. -
Keep the lead-up. Set
PreLogTimeandPostLogTimefor the data before and after the event. See REXGEN XML reference: recording (SD) and USB outputs. - Validate and load. Check the file against the schema, then load it. See REXGEN XML configuration: how it fits together.
Each product page lists the trigger sources that model offers: CAN identifier, signal, digital input, J1939 DM1 and internal channel.
Products in this guide
Still stuck?