K-AN8K-BOXK-TCPinout

K-Series link cables, termination and terminals

Updated

Choose the right cable to chain K-Series modules, connect them to a Kvaser interface, terminate the bus and wire the K-BOX and K-AN8 analogue inputs.

Which cable for which job

K-Series cables and adapters
Part number What it is Use it to
INF4305.0 9-way D-Sub male to 9-way D-Sub female, 300 mm Link one module's CAN out to the next module's CAN in (CAN and supply), or connect a module to a Kvaser CAN interface
INF4305.1 9-way D-Sub male to 9-way D-Sub male, 300 mm Connect two female sockets, for example a module's CAN out to a Kvaser T-CANnector
INF4308C 9-way D-Sub male to 9-way D-Sub female, fully pinned, 500 mm Connect a Kvaser T-CANnector v2 to a K-BOX
INF4310 120 Ω termination adapter, 9-way D-Sub Terminate the CAN bus at the last module
INF4211 25-way D-Sub female to 25-way D-Sub male, shielded, 200 mm Extend the K-BOX or K-AN8 analogue (ADC) connector
INF4214 25-way D-Sub female screw terminal Wire sensors to the K-BOX or K-AN8 analogue inputs

For every other Influx Technology cable, see Cables and accessories: part number index.

Supply limits on the link

The link cables carry the battery supply on pin 9 and do not regulate it. Never apply a higher voltage to pin 9 than the lowest-rated module on the chain accepts.

Supply range on pin 9, by module
Module Supply range
K-TC 4.5 to 31 V DC
K-BOX 6 to 36 V DC
K-AN8 6 to 36 V DC
A chain of modules on one CAN bus K-SERIES · DAISY CHAIN A chain of modules on one CAN bus REBELAUX/CAN1K-TC4.5 to 31 VK-BOX6 to 36 VK-AN86 to 36 VINF4305.0INF4305.0INF4310120 Ωfrom the loggerOwn supplyOwn supplyterminatorSupplyCANCAN in (left), CAN out (right)K-Series module, with its supply range on pin 9Link each module's CAN out to the next module's CAN in and plug the INF4310 into the last CAN out. Give each module its own CAN IDs. The link cables do not regulate the supply, so never put more on pin 9 than the lowest-rated module on the chain can take.
A chain of modules, CAN out to CAN in, with a terminator on the last CAN out.

INF4305.0 link cable

The K-Series link cable connects one module's CAN out to the next module's CAN in and carries the CAN bus and the supply. It also connects a module securely to a Kvaser CAN interface. Both connectors are 9-way D-Sub with screws, wired to CiA 303-1 for CAN and power.

The INF4305.0 cable: a short black cable with a 9-way D-Sub plug at one end and a 9-way D-Sub socket at the other, both with thumbscrews
INF4305.0 has a plug at one end and a socket at the other.
INF4305.0 specifications
Parameter Value
Length 300 mm
Conductors 24 AWG (0.5 mm)
Connector A 9-way D-Sub plug (male), screws
Connector B 9-way D-Sub socket (female), screws
Operating temperature −20 °C to +80 °C
Weight 68 g
Colour Black
INF4305.0, both ends
Pin Signal
2 CAN-L
3 Signal ground
5 Power ground
7 CAN-H
9 Battery supply, passed through (see the limits above)

Pins 1, 4, 6 and 8 are not connected.

INF4305.1 male to male cable

This cable changes a female socket with screw-lock nuts into a standard male plug, so you can join two female sockets. For example, it joins a module's CAN out connector to a Kvaser T-CANnector.

The INF4305.1 cable: a short black cable with a 9-way D-Sub plug at each end
INF4305.1 has a plug at each end.
INF4305.1 specifications
Parameter Value
Length 300 mm
Cable diameter 5.75 mm
Connector A 9-way D-Sub plug (male), nuts, for the Kvaser T-CANnector end
Connector B 9-way D-Sub plug (male), screws, for the K-Series CAN out end
Operating temperature −20 °C to +80 °C
Colour Black

Both ends use the same pins as INF4305.0:

  • Pin 2, CAN-L
  • Pin 3, signal ground
  • Pin 5, power ground
  • Pin 7, CAN-H
  • Pin 9, battery supply passed through

Pins 1, 4, 6 and 8 are not connected.

INF4308C Kvaser cable

This fully pinned 9-way D-Sub cable, wired pin to pin, connects a Kvaser T-CANnector v2 to a K-BOX.

INF4308C specifications
Parameter Value
Length 500 mm
Cable diameter 5.75 mm
Connections Fully pinned, pin to pin
Connector A 9-way D-Sub plug (male), nuts
Connector B 9-way D-Sub socket (female), screws
Operating temperature −20 °C to +80 °C
Colour Black

INF4310 termination adapter

Each end of a CAN bus needs a 120 Ω resistor across CAN-H and CAN-L. On a chain of K-Series modules, plug the INF4310 adapter into the CAN out connector of the last module.

The INF4310 termination adapter: a compact 9-way D-Sub adapter with an Influx Technology label
The terminator plugs straight into a CAN out connector.
A linear CAN bus with a terminator at each end CAN BUS · TOPOLOGY A linear CAN bus with a terminator at each end CAN-H CAN-L 120 Ω terminator 120 Ω terminator ECU ECU Logger Stub: keep it short Logger ground tied to the vehicle ground Terminate only the two physical ends of the bus. With the power off, CAN-H to CAN-L measures about 60 Ω.

For why termination matters and how to check it, see CAN bus wiring: termination, cable length and grounding.

DB25 extension and screw terminal

The K-BOX and K-AN8 analogue inputs sit on a 25-way D-Sub ADC connector. For the pin assignment, see these guides:

INF4211 25-way D-Sub extension cable
Parameter Value
Length 200 mm
Conductors 21 AWG (0.7 mm), shielded
Connections Fully pinned, pin to pin
Connector A 25-way D-Sub socket (female), screws
Connector B 25-way D-Sub plug (male), screws
Weight 148 g
Colour Black

The INF4214 screw terminal plugs onto the ADC connector, so you can wire sensors to the K-BOX or K-AN8 analogue inputs without soldering.

The INF4214 screw terminal: a black 25-way D-Sub hood with its socket at the bottom edge, supplied with two long jack screws, two short screws and a cable clamp
INF4214 25-way screw terminal.
INF4214 specifications
Parameter Value
Pins 25
Connector 25-way D-Sub socket (female)
Type Screw terminal
Operating temperature −20 °C to +80 °C
Weight 75 g

Next: K-CAL: installing the software and CAN interface drivers.

Products in this guide

K-AN8

Analogue to CAN converter

View K-AN8 Ask an engineer

K-BOX

Multi-sensor data acquisition

View K-BOX Ask an engineer

K-TC

Thermocouple data logger

View K-TC Ask an engineer

Still stuck?