Create a trigger
Make the logger start or stop recording when something happens: a CAN message arrives, a signal crosses a value, or one of the logger's own channels (accelerometer, gyroscope, GNSS, analog input) meets a condition.
Before you start
- A project is open and already contains what the trigger will watch. To trigger on the accelerometer, the project needs an
Accelblock; to trigger on a CAN message, a CAN bus with aBusblock. See Create a configuration.
Steps
The trigger wizard from start to finish, for a trigger on CAN message 0x7DF
Click
Triggerson the toolbar.The
Triggerspane opens.Click
New Trigger.The wizard slides in on the page
Select Trigger Action.Type a
Trigger Name, then choose theTrigger Action:Start LoggingorStop Logging.More options appear for
Start Logging.- For
Start Logging, set how long to record: type theLog Time (sec), or leave0to keep recording. To include the seconds before the event, type aPre- Trigger Time (sec). ClickNext. - On
Select Trigger Type, choose what the trigger watches and clickNext. - On
Define Trigger Condition, set the condition and clickNext. On
Finish Trigger, clickFinish.The trigger appears in the list with its
Activebox ticked and a description in words.

Page 1: the action
| Field | Meaning |
|---|---|
Trigger Name | The name shown in the list |
Trigger Action | Start Logging or Stop Logging |
Logger Initial State | Whether the logger is recording before the first trigger |
New Log On Event | Start a new log file at each event |
Log Time (sec) | How long to record after the event. 0 = Continuous logging |
After the First trigger event / After the Last trigger event | Shown when Log Time (sec) is not 0: count the time from the first event, or restart it at every new event |
Pre- Trigger Time (sec) | Seconds before the event to keep. 0 = No pre- trigger |
Debounce (msec) | Ignore repeats of the event within this time |
Destination partition | The partition the triggered log is written to, Master or a backup partition |
The Current Trigger line under the list describes the trigger as you build it. Hover it to read the whole description if it does not fit.
Page 2: the type

| Type | Triggers when |
|---|---|
Trigger by CAN Ident | A message with a given identifier arrives on the chosen Bus |
Trigger by Parameter Value | A signal from a database meets a condition |
Trigger by DM1 J1939 Counter | The J1939 DM1 fault count changes |
Trigger by Digital Channel | A digital input changes. Greyed until the project has a digital input channel |
Trigger by Internal Channel | One of the logger's own channels meets a condition |
Use LED indication for the trigger lets the trigger light an LED on the logger.
Page 3: the condition
For Trigger by Internal Channel, choose the Channel Type (ADC, Orientation, Accelerometer, Gyroscope, GNSS), the Channel, the Operand and the Value:

The Operand list:

The Between and Outside operands take two values.
For Trigger by CAN Ident, type the identifier in CAN Ident in hexadecimal, or pick a message from a database in the list above it:

What you should see

Config ▸ View Summary shows the full description, for example: "Start Logging only for 10 seconds after the FIRST trigger event, use 2 seconds Pre-trigger when Accelerometer Z > 1.5".
To change a trigger, select it and click Edit Trigger: the wizard opens with its values. Untick Active to keep a trigger in the project without using it.
Troubleshooting
| Symptom | Cause | What to do |
|---|---|---|
Next does nothing on the first page | No Trigger Action is chosen | Choose Start Logging or Stop Logging |
No channels are available for the selected type. | The project has no block of that kind | Cancel, add the block (for example Analog for ADC) and start again |
You have reached the maximum allowed triggers | The project already has as many triggers as the logger allows | Delete one first |
Trigger by Digital Channel is greyed | The project has no digital input channel | Add Dig In and add a channel to it |
Related
---
Written for REXDESK 1.0.0.791 (23 Nov 2026).