Block settings reference

What each block in the Tools pane adds to a configuration and the settings it offers. The pane has four groups, CAN, LIN, Channels and Transmitting; scroll it down to reach the last one. Drag a tile onto its box in the Configuration pane; click a block to open its settings; right-click a block to remove it.

CAN

TileAddsSettings
Log AllRecords every frame on the busNone
ErrorsRecords error framesNone
FilterRecords only the identifiers you listFrom CAN ID, To CAN ID (hexadecimal), … to pick from a database, Add, Close. The list on the left shows each range with an Active box
J1939Records J1939 traffic by address or PGNSource Address, Destination Address, PGN, Add, Close
UDS/CCPSends request messages and records the repliesOpens the Event messages window
CAN Filter
J1939 Filter Type

Event messages (UDS/CCP)

The window has two lists: SINGLE messages are sent once, REPEATABLE messages are sent again and again. Add asks which list the message goes in. Columns: TX, RX, Delay (ms), Time Out (ms), Attempt, Type, BRS, DLC, Data, Expected response, Comment. Import ▾ loads messages from a file.

Event messages

LIN

TileAddsSettings
Log AllRecords every frame on the LIN busNone
ScheduleMakes the logger run a LIN scheduleActive Schedule Table, … to load one; a list with Delay (ms) and buttons to reorder
LIN schedule

Channels

TileSettings
AnalogAnalog Channel, Sampling Rate (ms), and a scaling Coeff A, Coeff B (Formula: A*X + B). Add puts the channel in the list on the left; add one entry per input
Dig InDigital Channel, Sampling Rate (ms), Add
AccelRange, Sampling Rate (msec), Impact
GyroRange, Sampling Rate (msec)
GNSSSee Log GNSS data and draw geofence zones
OrientationMethod, Sampling Rate (msec)
IMU MappingHow the logger is mounted in the vehicle
DeviceSelect device channels: RTC, IMU_Temperature, MCU_Temperature
Add Analog Channel
Gyro
Orientation
Device channels

Transmitting

Scroll the Tools pane down to find this group. Drag a tile onto the Output box under Transmitting in the Configuration pane. Each can be added once.

TileAddsSettings
PeriodicMessages the logger sends at a fixed periodOpens the Periodic messages window (below)
HW InfoA request and reply pair for reading the logger's hardware information over CANOutput Bus, Rx Ident (0x101), Tx Ident (0x201)
SnapshotA snapshot file: chosen signals sampled at a fixed rateOpens the Snapshots window (below)
The Transmitting group
HW Info

Periodic messages

Adding a periodic message and linking a signal

  1. Drag Periodic onto Output.

    The Periodic block appears in Output and the Periodic messages window opens on the right.

  2. Click Add.

    A row is added with Tx Ident 0x001, Period (ms) 100, Type CAN Standard, DLC 8 and Data 00 00 00 00 00 00 00 00.

  3. Set the identifier, the period and the data, and tick the bus or buses (CAN 0 to CAN 3) the message is sent on.
Periodic messages
ControlWhat it is
Add, RemoveAdd a message; remove the selected one
Link Message Up, UnlinkLink the selected message to the one above it, or undo that. Available from the second message on (see Linked messages below)
Move Up, Move DownChange the order
Load ▾Load CSV replaces the list with the messages of a file; Import Kvaser Log
Save CSVSave the list to a file (see Save and load the list below)
Tx Ident, Period (ms), Delay (ms)Identifier and period of the message. Delay (ms) can only be set for a linked message
CAN 0 … CAN 3Tick the buses to send on
Type, BRS, Log Tx, DLC, DataFrame type (CAN Standard by default), bit-rate switch (grey for CAN Standard), also log the sent message, length, and the data bytes
Button at the end of the rowOpens Link signals to the selected message

To put live values into a message, click the button at the end of its row. In Link signals to the selected message, click + to add a row, choose the Signal, and set Start Bit and Bit Count. In a project with nothing else in it the Signal list offers TimeStamp, RTC and All frames from CAN 0 to All frames from CAN 3. Click OK. Once a signal is linked, Log Tx is ticked and Data is greyed for that message.

Link signals to the selected message

Linked messages. A linked message is sent after the message above it, on the same buses, instead of on a period of its own. Select the second message (or a later one) and click Link Message Up.

The Linked column shows a link, Period (ms) and the bus boxes of that message go blank, and Delay (ms) is set to 1.

Set Delay (ms) to the time to wait after the message above. Unlink makes it a message of its own again.

A message linked to the one above it

Save and load the list. Save CSV opens Save As and writes the list to a text file, one line per message, under this heading line:

Ident,Linked,Period,Delay,CAN 0,CAN 1,CAN 2,CAN 3,Type,BRS,DLC,Data
0x123,,250,,,1,,,,,8,00 00 00 00 00 00 00 00

A ticked box is written as 1, an unticked one is left empty, and Type is empty for CAN Standard. Log Tx is not written to the file.

Load ▾ ▸ Load CSV opens Open and reads such a file back.

Load CSV replaces the whole list without asking. Save the list first if you want to keep it.

Snapshots

Adding a snapshot file

  1. Drag Snapshot onto Output.

    The Snapshot block appears in Output and the Snapshots window opens.

  2. Click Add Snapshot File, type a Name, set Sampling Rate (sec) (10 by default) and Upload Rate (sec) (60 by default), and click OK.

    The file appears under Snapshot Files. Add Snapshot File turns grey: a configuration holds one snapshot file.

The Snapshot File panel
  1. Click Add Items ▾ and choose Add Signals or Add Internal Channels.
Add Items
  1. For Add Signals: in Select Items, click the folder button and open a DBC file, or choose one in Library File. Tick the signals and click OK.

    Each signal is listed with its Label, Ident and a Source.

  2. Choose the bus each signal comes from in Source (CAN 0 by default).
Snapshot items

Add Internal Channels lists the logger's own channels (GPS / GNSS, IMU, Digital inputs, Analog inputs). A grey row belongs to a source that is not in the project yet; the Status column says what to enable, and Enable source in project does it for the selected row.

To remove an item, select its row and click Remove Items. To remove a block, right-click it in Output.

Device Configuration

These tiles are always present at the bottom of the Configuration pane. Click one to open it.

TileSettings
StorageMax Logging Time and Max Log Size for the Master Partition: the logger closes a log and starts a new one when either is reached
EncryptEncryption Key (keys come from Tools ▸ Encryption Manager), Encrypt Datalogs, Encrypt AWS Credentials, Lock Device "(Only users that use this encyption key will be able to communicate with the device)"
UploadFTP upload: Store data to FTP, the Mobile and FTP accounts, check and status times. See Cloud Settings. With no account set up: No FTP settings found. Please add FTP from Tools -> Cloud Settings
SleepSleep mode, Sleep after no CAN activity for (minutes), and the wake-up sources Wake Up On CAN 0, Wake Up On CAN 1, Wake Up On Movement, Wake Up On Alarm
S3Cloud storage upload: Enable Cloud Storage (AWS, GCS), the Mobile and Cloud Storage accounts, check and status times. See Cloud Settings. With no account set up: No S3 settings found. Please add S3 from Tools -> Cloud Settings
LiveSwitches live data over USB on or off for this configuration. Needed for View live data
Encrypt
Sleep

---

Written for REXDESK 1.0.0.791 (23 Nov 2026).