REBEL CTREBEL LTSpecification

REBEL LT and REBEL CT: specifications

Updated

Look up the networks, inputs, storage, power figures, enclosure and ordering codes for REBEL LT and REBEL CT. You can also download the spec sheet for either logger.

Spec sheets

Each logger has a one-page spec sheet. The tables repeat its figures and add the detail installers ask for most.

Download the REBEL LT spec sheet (PDF, 53 KB)

Download the REBEL CT spec sheet (PDF, 52 KB)

REBEL LT

REBEL LT records two CAN buses, K-Line and four analogue channels, and runs UDS, XCP and OBD diagnostics on the same logger. Its ordering code is INF2101P.

Networks and protocols

REBEL LT networks and protocols
Item Specification
CAN 2 CAN 2.0B buses, up to 1 Mbit/s. Raw CAN messages or signals decoded with a DBC file.
K-Line 1 K-Line channel (ISO 9141) for legacy diagnostic communication
Protocols OBD, UDS to ISO 14229 and ISO 15765, CCP, XCP on CAN, SAE J1939, CAN monitoring
UDS services 0x1, 0x19, 0x21, 0x22, 0x23, 0x1A and 0x2C, with fast DAQ where the module supports it
CAN output Outputs CAN signals (for example to a display) and sends user-defined messages periodically
Gateway Moves signals from one CAN bus to the other while logging
Trigger conditions Up to 20 conditions: greater than, less than, equal to, increment, decrement or on change
Trigger actions Up to 20 triggers. Actions: start or stop logging, sample one-shot data, sample DTCs or read OBD data. Pre- and post-trigger times and LED functions are configurable.

Inputs

REBEL LT analogue and digital inputs
Item Specification
Analogue channels 4 bipolar single-ended inputs
Analogue range ±10 V
Maximum applied voltage ±40 V
Resolution 12-bit ADC
Sample rate Up to 1 kHz
Input impedance Above 50 kΩ
Digital channels 3 unipolar single-ended inputs or outputs. Digital I/O 3 doubles as the auxiliary power output +Vd.
Input thresholds Low below 2 V, high above 2.5 V, up to 36 V absolute maximum. Keep inputs within 0 to +12 V.
Output drive Open collector, collector-emitter voltage 36 V, collector current 50 mA maximum, saturation voltage below 0.6 V
Applied voltage on digital pins -0.5 V to 36 V absolute maximum. Keep digital inputs within 0 to +12 V.
Position Optional GNSS with an external antenna. DIALOG Standard shows the position on a GPS map.

To reach the analogue and digital channels, you need the INF4204.1 multi-connect cable. It is not in the standard REBEL LT package. See REBEL breakout cables: INF4203 and INF4204.1 multi-connect pinouts.

Storage, power and wake

REBEL LT storage, power and wake
Item Specification
Storage Removable SDHC card, 32 GB shipped, up to 64 GB. Use preformatted Influx Technology cards.
File system FAT32, readable on any PC
Configuration Over USB or on the SD card
Supply 4.5 to 36 V DC, 12 V typical, internally fused with reverse-polarity protection
Current at 12 V Logging 250 to 350 mA, sleep about 80 mA, power down under 2 mA
Wake WakeOnCAN on CAN 0 or CAN 1, or the wake-up pin. Powers down when both CAN buses go idle, after a delay you set.
Wake-up time Logging starts within 20 ms from sleep and in under 5 seconds from power down
PC interface Isolated USB 2.0, type B. You can power the logger from USB.
Connectivity Optional 4G LTE and 3G GPRS

Physical and environmental

REBEL LT enclosure and environment
Item Specification
Enclosure Stackable ABS. Stacks with K-TC, K-BOX, K-AN8 and other REBEL loggers.
Dimensions 115 × 105 × 26 mm (L × W × H)
Weight 400 g
Ingress protection IP20
Operating temperature -40 to +80 °C
Humidity 90% maximum
Isolation USB galvanic isolation. It protects the logger and the PC from voltage spikes and ground loops.
LEDs 9 status LEDs
Main connector 25-way D-Sub, male

REBEL CT

REBEL CT CAN FD records two CAN 2.0, two CAN FD and two LIN buses on one timeline. Diagnostics and gateway functions run on the same logger that records the bus. Its ordering code is INF2105.01P.

Networks and protocols

REBEL CT networks and protocols
Item Specification
CAN 2 CAN 2.0 buses and 2 CAN FD buses. CAN FD in ISO and non-ISO standard frames. Raw messages or signals decoded with a DBC file.
LIN 2 LIN channels
Protocols OBD and UDS to ISO 14229, CCP, XCP on CAN and SAE J1939
Gateway CAN 2.0 gateway while logging

Inputs and position

REBEL CT inputs and position upgrades
Item Specification
Analogue 4 analogue inputs, each independently calibratable. The multi-connect cable breaks them out.
Digital 3 digital input and output channels
GNSS 18 Hz GNSS module with an external antenna socket, available as an upgrade
Motion 1 kHz three-axis accelerometer and 3D gyroscope, available as upgrades

For the electrical limits of the analogue and digital pins, see REBEL CT: connector pinouts.

Storage and power

REBEL CT storage and power
Item Specification
Storage Extreme SDXC card behind a splash-proof flap, 64 GB shipped, 128 GB supported
Clock Battery-backed real-time clock
Supply 4.5 to 36 V DC from the vehicle
Current at 12 V Logging about 300 mA, sleep about 80 mA, deep sleep about 3 mA
Wake Low-power sleep with WakeOnCAN and WakeOnSignal
PC interface Isolated USB, type B
Connectivity Optional Wi-Fi and 4G LTE

Physical and environmental

REBEL CT enclosure and environment
Item Specification
Enclosure Aluminium, IP65 rated with a splash-proof cover. Stacks with the K-Series range.
Dimensions 126 × 110 × 35 mm (L × W × H)
Weight 370 g
Operating temperature -20 to +80 °C
Humidity 90% maximum
Isolation Galvanic isolation on USB and the enclosure, which isolates the measurement from the rig
Main connector 25-way D-Sub, male, broken out to 9-way D-Subs by the multi-connect cable

Software and export

Software in the box and export formats
Item REBEL LT REBEL CT
Software in the box DIALOG Configurator and Module Analyser Lite DIALOG Standard and Module Analyser Lite
Free software DIALOG Remote and DIALOG Configurator DIALOG Remote and DIALOG Configurator
Export MDF, MDF4, BLF and MAT MDF4, BLF, MAT and CSV

DIALOG Standard adds these features:

  • The live viewer
  • Graphical analysis
  • GPS maps
  • XCP and CCP measurement
  • The post-analysis oscilloscope

DIALOG Plus adds batch processing and data file merging. For the full version table, see REBEL LT and REBEL CT: overview and software.

What is in the box

Package contents
Logger Contents
REBEL LT (INF2101P) Logger, DIALOG Configurator, Module Analyser Lite, USB cable, INF4203 two CAN breakout cable, preformatted 32 GB SDHC card, 12-month SLA
REBEL CT (INF2105.01P) Logger, DIALOG Standard, Module Analyser Lite, INF4204.1 multi-connect breakout cable, USB cable, preformatted 64 GB Extreme SDXC card, 12-month SLA

For replacement cards, use SanDisk Extreme Pro SD cards. For cables and accessories, see Cables and accessories: part number index.

Next: REBEL LT: connector pinouts.

Products in this guide

REBEL CT

Automotive engineering logger

View REBEL CT Ask an engineer

REBEL LT

Vehicle diagnostics logger

View REBEL LT Ask an engineer

Still stuck?

Our engineers answer support questions on every Influx Technology product.