REBEL CTREBEL LTSpecification
REBEL LT and REBEL CT: specifications
Look up the networks, inputs, storage, power figures, enclosure and ordering codes for REBEL LT and REBEL CT. You can also download the spec sheet for either logger.
Spec sheets
Each logger has a one-page spec sheet. The tables repeat its figures and add the detail installers ask for most.
Download the REBEL LT spec sheet (PDF, 53 KB)
Download the REBEL CT spec sheet (PDF, 52 KB)
REBEL LT
REBEL LT records two CAN buses, K-Line and four analogue channels, and runs UDS, XCP and OBD diagnostics on the same logger. Its ordering code is INF2101P.
Networks and protocols
| Item | Specification |
|---|---|
| CAN | 2 CAN 2.0B buses, up to 1 Mbit/s. Raw CAN messages or signals decoded with a DBC file. |
| K-Line | 1 K-Line channel (ISO 9141) for legacy diagnostic communication |
| Protocols | OBD, UDS to ISO 14229 and ISO 15765, CCP, XCP on CAN, SAE J1939, CAN monitoring |
| UDS services | 0x1, 0x19, 0x21, 0x22, 0x23, 0x1A and 0x2C, with fast DAQ where the module supports it |
| CAN output | Outputs CAN signals (for example to a display) and sends user-defined messages periodically |
| Gateway | Moves signals from one CAN bus to the other while logging |
| Trigger conditions | Up to 20 conditions: greater than, less than, equal to, increment, decrement or on change |
| Trigger actions | Up to 20 triggers. Actions: start or stop logging, sample one-shot data, sample DTCs or read OBD data. Pre- and post-trigger times and LED functions are configurable. |
Inputs
| Item | Specification |
|---|---|
| Analogue channels | 4 bipolar single-ended inputs |
| Analogue range | ±10 V |
| Maximum applied voltage | ±40 V |
| Resolution | 12-bit ADC |
| Sample rate | Up to 1 kHz |
| Input impedance | Above 50 kΩ |
| Digital channels | 3 unipolar single-ended inputs or outputs. Digital I/O 3 doubles as the auxiliary power output +Vd. |
| Input thresholds | Low below 2 V, high above 2.5 V, up to 36 V absolute maximum. Keep inputs within 0 to +12 V. |
| Output drive | Open collector, collector-emitter voltage 36 V, collector current 50 mA maximum, saturation voltage below 0.6 V |
| Applied voltage on digital pins | -0.5 V to 36 V absolute maximum. Keep digital inputs within 0 to +12 V. |
| Position | Optional GNSS with an external antenna. DIALOG Standard shows the position on a GPS map. |
To reach the analogue and digital channels, you need the INF4204.1 multi-connect cable. It is not in the standard REBEL LT package. See REBEL breakout cables: INF4203 and INF4204.1 multi-connect pinouts.
Storage, power and wake
| Item | Specification |
|---|---|
| Storage | Removable SDHC card, 32 GB shipped, up to 64 GB. Use preformatted Influx Technology cards. |
| File system | FAT32, readable on any PC |
| Configuration | Over USB or on the SD card |
| Supply | 4.5 to 36 V DC, 12 V typical, internally fused with reverse-polarity protection |
| Current at 12 V | Logging 250 to 350 mA, sleep about 80 mA, power down under 2 mA |
| Wake | WakeOnCAN on CAN 0 or CAN 1, or the wake-up pin. Powers down when both CAN buses go idle, after a delay you set. |
| Wake-up time | Logging starts within 20 ms from sleep and in under 5 seconds from power down |
| PC interface | Isolated USB 2.0, type B. You can power the logger from USB. |
| Connectivity | Optional 4G LTE and 3G GPRS |
Physical and environmental
| Item | Specification |
|---|---|
| Enclosure | Stackable ABS. Stacks with K-TC, K-BOX, K-AN8 and other REBEL loggers. |
| Dimensions | 115 × 105 × 26 mm (L × W × H) |
| Weight | 400 g |
| Ingress protection | IP20 |
| Operating temperature | -40 to +80 °C |
| Humidity | 90% maximum |
| Isolation | USB galvanic isolation. It protects the logger and the PC from voltage spikes and ground loops. |
| LEDs | 9 status LEDs |
| Main connector | 25-way D-Sub, male |
REBEL CT
REBEL CT CAN FD records two CAN 2.0, two CAN FD and two LIN buses on one timeline. Diagnostics and gateway functions run on the same logger that records the bus. Its ordering code is INF2105.01P.
Networks and protocols
| Item | Specification |
|---|---|
| CAN | 2 CAN 2.0 buses and 2 CAN FD buses. CAN FD in ISO and non-ISO standard frames. Raw messages or signals decoded with a DBC file. |
| LIN | 2 LIN channels |
| Protocols | OBD and UDS to ISO 14229, CCP, XCP on CAN and SAE J1939 |
| Gateway | CAN 2.0 gateway while logging |
Inputs and position
| Item | Specification |
|---|---|
| Analogue | 4 analogue inputs, each independently calibratable. The multi-connect cable breaks them out. |
| Digital | 3 digital input and output channels |
| GNSS | 18 Hz GNSS module with an external antenna socket, available as an upgrade |
| Motion | 1 kHz three-axis accelerometer and 3D gyroscope, available as upgrades |
For the electrical limits of the analogue and digital pins, see REBEL CT: connector pinouts.
Storage and power
| Item | Specification |
|---|---|
| Storage | Extreme SDXC card behind a splash-proof flap, 64 GB shipped, 128 GB supported |
| Clock | Battery-backed real-time clock |
| Supply | 4.5 to 36 V DC from the vehicle |
| Current at 12 V | Logging about 300 mA, sleep about 80 mA, deep sleep about 3 mA |
| Wake | Low-power sleep with WakeOnCAN and WakeOnSignal |
| PC interface | Isolated USB, type B |
| Connectivity | Optional Wi-Fi and 4G LTE |
Physical and environmental
| Item | Specification |
|---|---|
| Enclosure | Aluminium, IP65 rated with a splash-proof cover. Stacks with the K-Series range. |
| Dimensions | 126 × 110 × 35 mm (L × W × H) |
| Weight | 370 g |
| Operating temperature | -20 to +80 °C |
| Humidity | 90% maximum |
| Isolation | Galvanic isolation on USB and the enclosure, which isolates the measurement from the rig |
| Main connector | 25-way D-Sub, male, broken out to 9-way D-Subs by the multi-connect cable |
Software and export
| Item | REBEL LT | REBEL CT |
|---|---|---|
| Software in the box | DIALOG Configurator and Module Analyser Lite | DIALOG Standard and Module Analyser Lite |
| Free software | DIALOG Remote and DIALOG Configurator | DIALOG Remote and DIALOG Configurator |
| Export | MDF, MDF4, BLF and MAT | MDF4, BLF, MAT and CSV |
DIALOG Standard adds these features:
- The live viewer
- Graphical analysis
- GPS maps
- XCP and CCP measurement
- The post-analysis oscilloscope
DIALOG Plus adds batch processing and data file merging. For the full version table, see REBEL LT and REBEL CT: overview and software.
What is in the box
| Logger | Contents |
|---|---|
REBEL LT (INF2101P) |
Logger, DIALOG Configurator, Module Analyser Lite, USB cable, INF4203 two CAN breakout cable, preformatted 32 GB SDHC card, 12-month SLA |
REBEL CT (INF2105.01P) |
Logger, DIALOG Standard, Module Analyser Lite, INF4204.1 multi-connect breakout cable, USB cable, preformatted 64 GB Extreme SDXC card, 12-month SLA |
For replacement cards, use SanDisk Extreme Pro SD cards. For cables and accessories, see Cables and accessories: part number index.
Next: REBEL LT: connector pinouts.