DIALOGK-AN8K-BOXK-TCREBEL CTREBEL LTManual

K-Series: logging module data with REBEL and DIALOG

Updated

Make a REBEL record the data a K-TC, K-BOX or K-AN8 sends. Power the module from the logger, add its bus in DIALOG and load its DBC file.

Before you start

From K-CAL to a REBEL recording K-CAL AND DIALOG · DBC FLOW From K-CAL to a REBEL recording K-CALConfigurechannels, IDsCommitto the moduleExportDBC fileDBC filefrom K-CALDIALOGAdd a busCAN 1 (MS)Add protocolCAN MonitorLoad the DBCImport tabPick signalsto DAQ listSendto the loggerREBEL recordsmodule messagesK-CAL configures the module and exports its DBC file; DIALOG loads that file into a CAN Monitor protocol on CAN 1 (MS), the bus the AUX/CAN1 lead carries. The bus baud rate in DIALOG must match the module's baud rate in K-CAL.
From K-CAL to a REBEL log.

Turn on aux power

When the module takes its power from the REBEL, run the REBEL from the vehicle or an external supply, not from USB alone. Then enable its auxiliary power output in the configuration.

  1. Open the configuration properties. In DIALOG, right-click the project you want to configure and select Properties. The Edit Configuration window opens.
  2. Enable auxiliary power. On the Settings tab, tick Aux Power On.
  3. Save the configuration. Select OK.
  4. Send it to the REBEL. Right-click the project and select Send Configuration to the Logger.

Choose a sleep mode

Select a sleep mode on the Sleep Mode tab of the same window. Use one of these:

  • Wake up on CAN 1 (MS) Activity
  • Wake up on CAN 0/1 (HS/MS) Activity
  • Power down Mode
DIALOG Edit Configuration window, Sleep Mode tab, with the Sleep Mode list open: No Sleep, Wake up on CAN 0 (HS) Activity, Wake up on CAN 1 (MS) Activity, Wake up on CAN 2 (Inst) Activity, Wake up on CAN 0/1 (HS/MS) Activity, Wake up on Alarm 1 and Power down Mode
The recommended modes are underlined.

Add the module's bus

The AUX/CAN1 lead carries the REBEL's CAN 1 (MS) bus, so add that bus to the project.

  1. Create a bus. Select the project and select New Bus.
  2. Choose CAN 1 (MS). In the Choose Bus list, select CAN 1 (MS) and select OK.
  3. Set the bus properties. The bit rate must match the module's bit rate in K-CAL.

Add a CAN Monitor protocol

  1. Create a protocol. With the new bus selected, select New Protocol.
  2. Choose CAN Monitor. In Choose Protocol Type, select CAN Monitor and select OK.
  3. Name it. Enter a Protocol Name and select OK. Tick Log All Channels only if you want every CAN message on the bus, not only the module's signals.
The New CAN Monitor Protocol window: Protocol Name CANMonitor1, Oversample Rate 10, and unticked boxes for Log All Channels and Log CAN signals at Slow Rate
With Log All Channels cleared, the REBEL records only the module's signals.

Load the DBC and pick signals

  1. Load the DBC file. On the Import tab, select Load DBC. Or open the DBC panel on the right side of the window and select its open file button. Select the DBC file you exported from K-CAL.
  2. Choose the signals. Select the signals you want in the DBC list, for example TC_0 to TC_7.
  3. Copy them to the DAQ list. Select Copy Items, then paste the signals into the DAQ list of the CAN Monitor protocol.
  4. Send the configuration. Right-click the project and select Send Configuration to the Logger.

One configuration can hold several buses, so the REBEL can log OBD, A2L or ODX data alongside the module. For more on DIALOG buses and signals, see DIALOG: record raw CAN frames or DBC signals with a REBEL.

Watch: use the TC modules with REBEL data loggers (1:56)

Check the LEDs

When the bit rate in the project matches the module, the REBEL shows:

  • The status LED solid orange
  • The CAN LED solid green

If the CAN LED flashes green, the CAN bus is misconfigured. Check the bit rate and the termination. See CAN bus wiring: termination, cable length and grounding.

To copy and export the logs, see DIALOG: view live data, copy recordings and export them.

This guide ends the setup series. To start again, see K-Series: connecting and powering modules.

Products in this guide

DIALOG

CAN analysis & diagnostics

View DIALOG Ask an engineer

K-AN8

Analogue to CAN converter

View K-AN8 Ask an engineer

K-BOX

Multi-sensor data acquisition

View K-BOX Ask an engineer

K-TC

Thermocouple data logger

View K-TC Ask an engineer

REBEL CT

Automotive engineering logger

View REBEL CT Ask an engineer

REBEL LT

Vehicle diagnostics logger

View REBEL LT Ask an engineer

Still stuck?

Our engineers answer support questions on every Influx Technology product.