K-BOXSpecification
K-BOX: overview and specifications
Find out what K-BOX measures, how it reaches your logger and the full specification, so you can plan the channels, power and wiring before you install it.
This is step 1 of the six-part K-BOX series. The series covers:
- The specification
- The connector pinouts
- Setting up channels in K-CAL
- The digital measurement modes
- Conversion tables and formulas
- Calibration and firmware
What K-BOX does
K-BOX (INF2201) is the multi-DAQ module of the K-Series. It measures thermocouples, voltages, currents and PWM signals at the same time and sends the results periodically on the CAN bus. The measurement data is time synchronised with the vehicle network data your logger records.
K-BOX has no storage of its own. Any CAN logger records it, such as a REBEL, a REXGEN or a third-party logger. A DBC file describes the messages, so any tool that reads DBC files decodes them. Set the CAN IDs, rates, ranges and calibration in K-CAL. K-BOX keeps them when the power is off.
- Stack it with other K-Series modules. The two CAN connectors carry CAN and power from one module to the next.
- Use it for applications with many thermocouples and analogue inputs.
- Leave it on a vehicle. WakeOnCAN and deep sleep suit unattended fleet installs.

How K-BOX connects to a logger
K-BOX connects to the outside world only through CAN. It has no PC port, so you configure it in K-CAL through a CAN interface or an Influx Technology logger.
- With a REBEL logger: the REBEL can power the module through the multi-connect cable when its auxiliary power output is enabled.
- With a REXGEN logger: give the module an external supply. A REXGEN does not provide power for a K-Series module.
- In a stack: give every extra module an external supply.
For each case in detail, see these guides:
- K-Series: connecting and powering modules
- K-CAL: installing the software and CAN interface drivers
- K-Series: logging module data with REBEL and DIALOG
Key features
- Eight bipolar differential analogue inputs on software switchable ranges of ±80 V, ±40 V, ±20 V or ±10 V.
- Up to eight type J, K or T thermocouples with cold junction compensation.
- Four digital channels, three of which measure frequency, pulses, duty cycle, events or RPM up to 100 kHz.
- Regulated 5 V and 24 V outputs to power external sensors.
- Current measurement on the analogue inputs through a current clamp or shunt.
- Galvanic isolation between the enclosure, power, CAN bus, analogue board and thermocouple board.
- Configuration through a DBC file and K-CAL for Windows.
Specifications
These tables give the full K-BOX specification.
Power and interfaces
| Item | Specification |
|---|---|
| Supply voltage | 6 to 36 V DC |
| Power consumption | Typically under 3 W |
| Power saving | WakeOnCAN and power-down deep sleep |
| Sensor supply outputs | Regulated 5 V and 24 V, 80 mA combined |
| CAN interface | CAN 2.0, data transmitted periodically and time synchronised with the vehicle network data |
| PC interface | None. Configure over CAN in K-CAL through a CAN interface or an Influx Technology logger |
| Signal definition | DBC file, exported from K-CAL |
| Settings | Stored in the module and kept without power |
| Isolation | Galvanic isolation between enclosure, power, CAN bus, analogue board and thermocouple board |
| Indicators | Two LEDs, Status and CAN |
Analogue inputs
| Item | Specification |
|---|---|
| Channels | 8 bipolar differential inputs |
| Ranges | Software switchable ±80 V, ±40 V, ±20 V or ±10 V |
| Resolution | 16 bit |
| Accuracy | ±0.0015% of full scale |
| Sampling rate | 1 kHz on all 8 channels, 2 kHz on 4 or 10 kHz on 2 |
| Input impedance | Above 4 MΩ |
| Over-voltage protection | ±150 V on the analogue channels |
| Current | Measured on the analogue inputs through a current clamp or shunt |
Thermocouple inputs
| Item | Specification |
|---|---|
| Channels | Up to 8, type J, K or T |
| Compensation | Automatic cold junction compensation |
| Range | −200 °C to +1250 °C |
| Accuracy | ±1 °C |
| Resolution | 0.1 °C |
| Sampling rate | 10 Hz on all 8 channels |
| Maximum input voltage | ±3.3 V |
| Connectors | Miniature flat-pin thermocouple sockets |
Digital inputs and outputs
| Item | Specification |
|---|---|
| Channels | 4 unipolar single-ended channels, each set up as an input or an output |
| Measurement inputs | Digital 1 to 3, for pulse duration, frequency, duty cycle, event count, cycle duration or RPM, up to 100 kHz |
| Pulse timing | Minimum pulse 100 ns, minimum 10 µs between pulses |
| Input thresholds | Low below 1.5 V, high above 2.0 V, up to 12 V |
| Input voltage range | −8 V to +12 V |
| Input leakage current | Under 10 nA |
| Outputs | Open collector outputs, 45 V and 10 mA maximum |
| Saturation voltage, output on | Under 0.15 V |
| Equivalent on-resistance | Under 510 Ω |
| Leakage current, output off | Under 5 µA |
Enclosure and environment
| Item | Specification |
|---|---|
| Enclosure | Stackable, daisy-chainable ABS |
| Ingress protection | IP65 |
| Dimensions | 115 × 105 × 79 mm |
| Weight | 450 g |
| Operating temperature | −40 °C to +85 °C |
| Humidity | Up to 90% |
| Connectors | 25-way D-Sub for the analogue inputs, two 9-way D-Sub for CAN in and out, 8 thermocouple sockets |
| Part number |
INF2201, sold as the INF2201P package |
Download the K-BOX spec sheet (PDF, 53 KB)
Warranty, calibration and support
K-BOX carries a 12-month warranty. See the returns and warranty policy. Influx Technology offers calibration and certification on demand. You can also calibrate the inputs yourself in K-CAL, in step 6 of this series. For help with a module, contact technical support.
Next: K-BOX: connector pinouts.
Products in this guide
Still stuck?
Our engineers answer support questions on every Influx Technology product.