REBEL CTREBEL LTPinout

Legacy REBEL cables: INF4100, INF4202 and the CT FlexRay port

Updated

Find the pinouts of discontinued REBEL hardware: the REBEL 100 start-up kit harness, the INF4202 breakout cable and the expansion port of the REBEL CT FlexRay variant. They are kept for owners of existing units. The REBEL 100 and the REBEL CT FlexRay are both discontinued, and no current Influx Technology product supports FlexRay.

Before you use this page

This guide covers hardware that is no longer sold. For current REBEL loggers, see these guides.

The current REBEL CT is the CAN FD variant. It has 2 CAN 2.0 buses, 2 CAN FD buses and 2 LIN channels, and no expansion port.

The tables come from earlier documentation, which has gaps and some conflicts. The conflicts are noted beside the tables. Check a cable with a meter before you rely on a pin. For help with a legacy unit, contact technical support.

INF4100 REBEL 100 start-up kit harness

The REBEL 100 was built for long-term event monitoring on production machinery, so it used an ECU-style automotive connector. This harness broke that connector out to standard 9-way D-Subs for engineering development. It did the same job as the REBEL CT multi-connect cable.

INF4100 specifications
Item Value
Length 890 mm
Connector A Automotive connector, Cinch 581-01-30-065, to the logger
Connector B 9-way D-Sub plug, CAN 0, CAN 1, K-Line and power
Connector C 9-way D-Sub, CAN 1
Connector D 9-way D-Sub, CAN 2
Connector E 9-way D-Sub, CAN 3
Connector F 15-way D-Sub, digital and analogue
Operating temperature -20 to +80 °C (harness only)
Weight 469 g

Earlier documentation gives different genders for several connectors. The lead tables below follow the lead pinouts.

Logger socket

All 30 pins of the Cinch logger socket
INF4100 logger socket, Cinch 30-way
Pin Signal
1A CAN-L, CAN 1
2A CAN-H, CAN 1
3A Digital I/O 0
1B CAN-L, CAN 0
2B CAN-H, CAN 0
3B Digital I/O 1
1C CAN-L, CAN 3
2C CAN-H, CAN 3
3C Digital I/O 2
1D CAN-L, CAN 2
2D CAN-H, CAN 2
3D Digital I/O 3
1E K-Line
2E Wake-up
3E Supply, 6 to 41 V
1F Erase
2F Ground
3F Power ground
1G Analogue input 3
2G Analogue ground
3G USB +5 V
1H Analogue input 2
2H Analogue ground
3H USB ground
1J Analogue input 1
2J Analogue ground
3J USB D+
1K Analogue input 0
2K Analogue ground
3K USB D−

The socket table gives the supply on pin 3E as 6 to 41 V. The lead B table gives 4.5 to 41 V.

CAN0/CAN1/K-Line/PWR lead

INF4100 CAN0/CAN1/K-Line/PWR lead, male 9-way D-Sub with screws
Pin Signal
1 CAN-L, CAN 1
2 CAN-L, CAN 0
3 Ground
4 K-Line (ISO 9141)
5 Power ground
7 CAN-H, CAN 0
8 CAN-H, CAN 1
9 Supply, 4.5 to 41 V

CAN 1, CAN 2 and CAN 3 leads

INF4100 CAN 1, CAN 2 and CAN 3 leads, 9-way D-Sub
Pin CAN 1 lead (female, screws) CAN 2 lead (male, nuts) CAN 3 lead (male, nuts)
2 CAN-L, CAN 1 CAN-L, CAN 2 CAN-L, CAN 3
3 Ground Power ground Power ground
5 Ground Not connected Not connected
7 CAN-H, CAN 1 CAN-H, CAN 2 CAN-H, CAN 3

Digital and analogue lead

INF4100 digital and analogue lead, 15-way D-Sub
Pin Signal
2 Digital I/O 1
4 Ground
5 Erase
6 Analogue ground
7 Analogue input 1
8 Analogue input 3
9 Digital I/O 0
10 Digital I/O 2
11 Ground
13 Wake-up
14 Analogue input 0
15 Analogue input 2

On this harness, keep digital inputs within 0 to +12 V, digital outputs within 50 mA and analogue inputs within -10 to +10 V.

INF4202 expansion port breakout cable

INF4202 connects to the expansion port of the discontinued REBEL CT FlexRay and REBEL CT 7 loggers. It breaks the port out to separate 9-way D-Subs for two FlexRay channels, three CAN buses and one LIN bus. The LIN bus shares a lead with CAN 4.

INF4202 specifications
Item Value
Length 700 mm
Wire 22 AWG, 0.6 mm
Connector A 15-way micro-D socket, 1.27 mm pitch, to the logger's expansion port
Connector B 9-way D-Sub socket, CAN 4 and LIN 3
Connector C 9-way D-Sub socket, CAN 5
Connector D 9-way D-Sub socket, CAN 6
Connector E 9-way D-Sub plug, FlexRay channel A
Connector F 9-way D-Sub plug, FlexRay channel B
Operating temperature -20 to +80 °C
Weight 236 g

Expansion port connector

INF4202 expansion port connector, female 15-way micro-D
Pin Signal
1 CAN-L, CAN 4 (extension 1)
2 CAN-H, CAN 4 (extension 1)
3 CAN-L, CAN 5 (extension 2)
4 CAN-H, CAN 5 (extension 2)
5 CAN-L, CAN 6 (extension 3)
6 CAN-H, CAN 6 (extension 3)
7 LIN bus
8 +Vin supply
9 FlexRay 1 BP
10 FlexRay 1 BM
11 FlexRay 2 BP
12 FlexRay 2 BM
13 Ground for the FlexRay buses
14 Ground for the CAN and LIN buses
15 Power ground

CAN and LIN leads

INF4202 CAN leads, female 9-way D-Sub
Pin CAN 4 and LIN 3 lead CAN 5 lead CAN 6 lead
2 CAN-L, CAN 4 CAN-L, CAN 5 CAN-L, CAN 6
3 CAN and LIN ground CAN and LIN ground CAN and LIN ground
4 LIN 3 Not connected Not connected
5 Power ground Power ground Power ground
7 CAN-H, CAN 4 CAN-H, CAN 5 CAN-H, CAN 6

FlexRay leads

INF4202 FlexRay 1 and FlexRay 2 leads, male 9-way D-Sub
Pin FlexRay 1 lead FlexRay 2 lead
2 FlexRay 1 BM FlexRay 2 BM
3 FlexRay ground FlexRay ground
5 Power ground Power ground
7 FlexRay 1 BP FlexRay 2 BP

REBEL CT FlexRay expansion port

On the discontinued REBEL CT FlexRay and REBEL CT 7 loggers, the expansion port is labelled FlexRay/LIN and CAN Ext. It is a male 15-way micro-D connector, 1.27 mm pitch, with nuts. It carries CAN 4 to CAN 6, one LIN bus, two FlexRay channels and the supply. Its pin assignment matches the INF4202 expansion port connector above.

Pins not listed in these tables are not connected.

Products in this guide

REBEL CT

Automotive engineering logger

View REBEL CT Ask an engineer

REBEL LT

Vehicle diagnostics logger

View REBEL LT Ask an engineer

Still stuck?

Our engineers answer support questions on every Influx Technology product.