K-AN8Pinout
K-AN8: connector pinouts
Use these tables to wire power, CAN, sensors and loads to K-AN8, and to stay within the limits of each pin.
Connectors at a glance
K-AN8 (INF2210) has the same CAN and analogue connectors as K-BOX, without the thermocouple sockets:
- Two 9-way D-Sub CAN connectors with nuts, one male and one female. Both carry the same signals, so CAN and power pass through a stack of K-Series modules.
- One 25-way male D-Sub, labelled ADC, for the eight analogue inputs and the sensor supplies.
- Two LEDs, labelled Status and CAN.
Pins missing from the tables are not connected.
CAN connectors
| Pin | Function |
|---|---|
| 1 | Digital 4 output, or +4.5 V instrumentation supply |
| 2 | CAN-L |
| 3 | Ground |
| 4 | Digital 1, input or output |
| 5 | Power ground |
| 6 | Digital 3, input or output |
| 7 | CAN-H |
| 8 | Digital 2, input or output |
| 9 | Supply voltage, 6 to 36 V DC |
Digital inputs and outputs
The four digital pins work as inputs or as outputs. Digital 1 to 3 also measure frequency, counts and pulses up to 100 kHz.
As inputs
- Keep the voltage between −8 V and +12 V.
- An input reads low below 1.5 V and high above 2.0 V.
As outputs
K-AN8 has four open collector outputs. Each switches a load to ground and is rated 45 V and 10 mA.
- Use them to switch relay coils, indicators and logic inputs.
- Supply the load from an external source and fit a flyback diode across a relay coil.
- Drive larger loads through a relay.
Set up the outputs in K-CAL. K-AN8 sends the output states on CAN with its measurements.
For every input and output circuit, see REBEL and K-Series: wiring the wake-up pin and digital I/O.
ADC connector
The ADC connector is a 25-way male D-Sub with nuts. Each analogue input is a differential pair. For example, input 0 uses pins 6 and 18, and input 7 uses pins 13 and 25.
| Pin | Function |
|---|---|
| 1 | +24 V sensor supply output |
| 2 | +5 V sensor supply output |
| 5 | Analogue ground |
| 6 | Analogue input 0 positive |
| 7 | Analogue input 1 positive |
| 8 | Analogue input 2 positive |
| 9 | Analogue input 3 positive |
| 10 | Analogue input 4 positive |
| 11 | Analogue input 5 positive |
| 12 | Analogue input 6 positive |
| 13 | Analogue input 7 positive |
| 14 | Ground out |
| 15 | Ground out |
| 17 | Analogue ground |
| 18 | Analogue input 0 negative |
| 19 | Analogue input 1 negative |
| 20 | Analogue input 2 negative |
| 21 | Analogue input 3 negative |
| 22 | Analogue input 4 negative |
| 23 | Analogue input 5 negative |
| 24 | Analogue input 6 negative |
| 25 | Analogue input 7 negative |
- Sensor supplies: the +24 V and +5 V outputs share 80 mA between them.
- Analogue inputs: do not apply voltages outside the range you set for the channel in K-CAL. The maximum is ±75 V to analogue ground and ±150 V between analogue inputs.