REXGEN: update the firmware and set the clock

Updated

Update the firmware on any REXGEN logger with REXDESK, then format its storage, send your configuration again and set its clock. The same steps apply to REXGEN 1, REXGEN 2, REXGEN 2 IMU GNSS, REXGEN Air and REXGEN Pro.

Before you update

Firmware updates for REXGEN 1, REXGEN Air and REXGEN Pro are digitally signed, so the logger accepts only firmware from a trusted source.

Update the firmware

  1. Open the reflash tool. In REXDESK, with the logger connected, select Reflash on the Device menu.
    REXDESK Device menu open, listing Live, Internal Storage, Set Device Time and Reflash, with Reflash highlighted
  2. Select the firmware. Select RexFirmware.zip from the REXDESK firmware folder and start the update.
  3. Wait for it to finish. The logger disconnects from the PC while it updates. On REXGEN 2, REXGEN 2 IMU GNSS and REXGEN Air, LED 1 and LED 2 flash alternately. REXGEN 1 flashes its single LED. Do not disconnect the logger until the LEDs stop flashing.
  4. Let it reconnect. The logger reconnects to REXDESK on its own when the update completes.
  5. Format the internal storage. Open Internal Storage and select Format SD. This formats the logger's eMMC.
  6. Send your configuration again. Open your project and select Run, so the logger runs your configuration on the new firmware.
Updating the firmware, step by step REXGEN · FIRMWARE Updating the firmware, step by step 1 Download logs formatting later erases them 2 Device > Reflash in REXDESK, with the logger connected 3 Pick the firmware RexFirmware.zip from the REXDESK firmware folder 4 Update runs LEDs flash and the logger disconnects. Do not disconnect it or change the supply 5 Logger reconnects on its own when the update completes 6 Format SD in Internal Storage: formats the eMMC 7 Run sends your configuration again 8 Set Time Synchronise with PC or a custom time Never roll back to older firmware: recorded data is lost. A dashed box is optional. REXGEN 1 flashes its single LED; the others flash LED 1 and LED 2 in turn. REXGEN Pro connects to REXDESK over the network, not USB.

Watch: Update the firmware for a REXGEN (0:55)

REXGEN Air and REXGEN Pro can also receive configuration and firmware updates over the air. See these guides.

Set the clock

Every log is stamped by the logger's real-time clock (RTC), so set it before you record.

  1. Open the clock settings. With the logger connected, select Set Time on the toolbar. REXDESK shows the logger's current time.
  2. Choose the time source. Select Synchronise with PC to copy the PC's clock, or Set Custom Date Time to enter a date and time yourself.
  3. Save it. Select Set Time.
Set Time window showing the logger time, with Synchronize with PC selected, a Set Custom DateTime option and a Set Time button
The Set Time window shows the logger's current time before you change it.

A REXGEN logger can also synchronise its clock from a CAN message. You set this in the configuration.

Check the RTC battery

A battery keeps the clock running while the logger has no power. If logs carry the wrong timestamp after you set the time, check the RTC battery first. It may not be switched on.

Watch: How to switch on the REXGEN RTC battery (0:27)

If the clock still drifts or resets, contact technical support.

Products in this guide

REXGEN 1

Vehicle black box

View REXGEN 1 Ask an engineer

REXGEN 2

Evidence data logger

View REXGEN 2 Ask an engineer

REXGEN 2 IMU GNSS

Motion & location data logging

View REXGEN 2 IMU GNSS Ask an engineer

REXGEN Air

CAN to cloud

View REXGEN Air Ask an engineer

REXGEN Pro

Edge data platform

View REXGEN Pro Ask an engineer

Still stuck?

Our engineers answer support questions on every Influx Technology product.