top of page
TempBanner.png
ReXgen2IMU_Shop.png

ReXgen 2 IMU

2x CAN/ CAN FD with 
LIN, Digital, Analog Inputs & Gyro

Delivered with ReXdesk -intuitive, configuration and analysis software
Buy now for...
Shop%20Icon_edited.png
Key Features
ReXgen 2 IMU
Software

ReXgen 2 IMU: Harness Reliable Data Wherever You Roam!

ReXgen 2 with the power of GNSS Positioning System and a 6D IMU

Rexgen 2 IMU comes with an integrated, highly-advanced and accurate GNSS module (using U-Blox Neo M8 Series)

One interface:

  Evaluate signals from the GNSS (QZSS, GLONASS, BeiDou and Galileo) satellites

  With a position accuracy of 2.0m CEP

  Log GNSS data at sampling rates of up to 18HZ

  Send your GNSS data to eMMC storage or CAN with support for up to 13 different parameters such as position input, speed, altitude etc

    

And thats not all:

  Acceleration output of ±2/±4/±8/±16 g at full scale at max sampling rate-1KHz

  Gyroscope’s angular output data rate- up to 1KHz with ±125/±250/±500/±1000/±2000 dps at full scale

16GB.png

ReXgen 2 IMU 16GB eMMC

GNSS (P/N: INF2112.02)

32GB.png

ReXgen 2 IMU 32GB eMMC

GNSS (P/N: INF2112.03)

InfluxCover3_edited.jpg
ReXgen2_B Logo.png

The ReXgen 2 IMU is an upgraded version of the ReXgen 2, with added GNSS, gyro, and accelerometer support.

It offers the same durability and cost-effectiveness as its predecessor but is geared towards applications that require a CAN 2.0, CAN FD, or LIN flight data recorder, with vibration and position tracking even in GPS-signal-absent environments. The ReXgen 2 IMU is ideal for recording data for shared cars, motorcycles, or off-road vehicles.

 

It doesn't need to be connected to a computer to record data and comes with configuration software that supports silent mode, CAN monitoring, message filtering, SAE-J1939 logging, and event triggering. 

The ReXgen 2 features to manage sensitive data:

 Mountable enclosure 

Data is stored securely on a non-removable embedded EMMC 

 Data encryption

 Real-time clock to timestamp data for analysis

Easy configuration :

Connect the ‘ReXgen 2 IMU’ to your computer and configure the device to work with your vehicle using the included configuration tool ReXdesk, or configure it using your custom applications with our open API.

 

Construction & Design:

Robust, stainless steel mounting screws withstand the toughest conditions. Secure the ReXgen and get ready to log /view live data.

 

Internal Storage to keep your data intact:

Inbuilt eMMC storage, that can be processed by custom-made algorithms, providing important alerts and statistics.  

One interface:

Connect the 'ReXgen 2 IMU' to a computer and configure the device to work with your vehicle; it supports CAN, J1939 and error logging

Create easily customised programs for your communication needs with the Pass-Thru (J2534) and connect by using USB 2.0 interface 

Compatible with third-party tools like SavvyCAN

Power Consumption

Power consumption is an important aspect when battery life is considered in electric or internal combustion vehicle. Will the data logger drain the battery when the vehicle is powered down? Or can you leave it on the vehicle for months with confidence?


All our data loggers support Wake On CAN 
The ReXgen2 supports Wake on Movement.

With advance features such as Power down mode and Sleep Mode the power consumption is the equivalent to 1mA per hour.

  • What are the supported data formats?
    CSV, MF4, MAT, ASC, blf
  • CAN we monitor live data?
    Yes, options for Live trace are available.
  • Is it possible to have 4 channels CAN FD?
    Yes, there are separate products supporting that function.
  • What are the main features available with ReXdesk?
    CAN live view, filter, trigger, sleep modes, DBC option.
  • Why is ReXgen not getting interfaced with the RexDesk?
    Please ensure that you have installed the driver. If not, you can find it under the Influx technology folder under the start menu
  • What happens if the logger storage gets full?
    The logger can continue logging after deleting the first file on a FIFO basis or can stop logging and be configured via ReXdesk, which has the option to format the logger. (FIFO is enabled by default.)
  • Is it possible to interface ReXgen 2 with KBOX?
    Yes, It will work with Kbox, but you will need to power the KBox from a separate power source since ReXgen doesn’t have Auxilary Power Out
  • Where can I find the Pinout details for ReXgen 2?
    You can find that under the help section in the ReXdesk software
  • Where can I get the Driver installation process?
    It is available under the Influx Technology folder in the Start menu. If it is not available there, then please install it from the Influx Technology support page. https://www.influxtechnology.com/support
  • What is the current consumption of ReXgen 2?
    <87mA in full operation and <2mA when CAN is not active
  • How to get real-time physical data?
    ReXgen doesn't provide real-time physical data, the user will have to retrieve the data log and post-process using a DBC file to view the physical data
  • Where can I find the Pinout details for ReXgen 2 IMU?
    You can find that under the help section in the ReXdesk software
  • What is the GNSS accuracy for ReXgen 2 IMU?
    2.5m CEP
  • What is the current consumption of ReXgen 2 IMU?
    <87mA in full operation and <2mA when CAN is not active
  • What happens if the logger storage gets full?
    The logger can continue logging after deleting the first file on a FIFO basis or can stop logging and be configured via ReXdesk, which has the option to format the logger. (FIFO is enabled by default.)
  • Is it possible to interface ReXgen 2 IMU with KBOX?
    Yes, It will work with Kbox, but you will need to power the KBox from a separate power source since ReXgen doesn’t have Auxilary Power Out
  • Are there any other connectors available apart from DB9?
    No, But modifications can be done for bulk orders on demand.
  • Where can I get the Driver installation process?
    It is available under the Influx Technology folder in the Start menu. If it is not available there, then please install it from the Influx Technology support page. https://www.influxtechnology.com/support
  • How to get real-time physical data
    User needs to use the DBC file, and post-collection, it can be exported as CSV
  • Does the ReXgen logger LEDs indicate the status of GNSS logging
    No. It is advised to wait 2 Mins before starting your trial, to a minimum number of 4 satellites.
  • Why does it support only DBC?
    The logger is only capable of logging CAN signal.
  • Is it possible to see a live trace with ReXgen 2 IMU?
    Yes
  • Where can I find the Pinout details for ReXgen Air?
  • What is the current consuption of ReXgen Air?
    <300mA in full operation and <2mA when CAN is not active
  • What happens if the logger storage gets full?
    The logger can continue logging after deleting the first file on a FIFO basis or can stop logging and be configured via ReXdesk, which has the option to format the logger. (FIFO is enabled by default.)
  • Can we interface ReXgen with KBOX?
    Yes, It will work with Kbox, but you will need to power the KBox from a separate power source since ReXgen doesn’t have Auxilary Power Out
  • Where can I get the Driver installer?
    It is available under the Influx Technology folder in the Start menu. If it is not available there, then please install it from the Influx Technology support page. https://www.influxtechnology.com/support
  • How to get real-time physical data?
    ReXgen doesn't provide real-time physical data, the user will have to retrieve the data log and post-process using a DBC file to view the physical data
  • Why is my ReXgen AIR not uploading data to FTPS server?
    There could be several reasons: 1) Ensure that the SIM card is active and has sufficient data 2) Ensure that the GPRS/LTE antenna is connected to the Logger 3) Check the Server and APN settings of the logger
  • Will I be supplied a SIM card
    No SIM card will be supplied. Most standard SIMs are suitable. If in doubt please ask our support team.
  • CAN we monitor live data?
    Yes, options for Live trace are available.
  • Why my logger is not getting Detected?
    Make sure that the ReXgen Driver is installed on your computer; refer ReXgen Support page for instructions.
  • Why is ReXdesk not opening after installation?
    Make sure that Visual C++ Redistributable x64 is installed.
  • Why does exported CSV data have gaps in it?
    ReXdesk Doesn’t export data after Interpolation or Resampling; the data is recorded and timestamped as received from the CAN bus. The gaps will be due to the difference in the transmission rate of various CAN messages.

Interested? Get in touch!

Phone-Icon.png
Email-Icon.png
+44 (0) 1525 842504

For more information, or to find your nearest team: